Remote menu operation
An optional remote plug is available to enable operating
the camera mode and set buttons by remote control.
Confirm the plug is properly wired as indicated in the
figure and connect it to the rear panel Remote connector.
Do not connect anything to the unused Pins.
1
5
3
8
2
9
10
12
11
6
7
4
Remote plug(option)
UP
DOWN
SET
Pin
Signal Abbrev.
Remarks
1
Not connected
N.C.
Do not connect
2
Serial
data
input
Tx
Connect to RS-232C
data terminal
3
Serial
data
output
Rx
Connect to RS-232C
data terminal
4
Up key
UP
Key switch connection
5
Down key
DOWN
Key switch connection
6
Not connected
N.C.
Do not connect
7
Not connected
N.C.
Do not connect
8
Set key
SET
Key switch connection
9
Not connected
N.C.
Do not connect
10
GND GND
Connect
to
RS-232C
ground
11
Not connected
N.C.
Do not connect
12
Not connected
N.C.
Do not connect
Remote operation with RS-232C
Signals 2, 3 and 10 can be used for control by personal
computer. Consult dealer for retailed information.
External key switch connections for remote operation
Keep the distance between the remote plug and
external key switches to less than about 2 meters.
Disconnect the remote plug from the camera Remote
connector when not using the key switches.
NOTE
Be sure to switch off the camera power before
connecting or disconnecting the remote plug.