25
PJ-TX10 (C10H)
6-11 Related Messages
When the unit's power is ON, messages such as those shown below may be displayed. When any such mes-
sage is displayed on the screen, please respond as described below.
Message
Description
CHANGE THE LAMP
AFTER REPLACING LAMP,
RESET THE LAMP TIMER.
(*1)
Lamp usage time is approaching 2000 hours. (*2)
Preparation of a new lamp, and an early lamp change is recommended. After you have
changed the lamp, please be sure to reset the lamp timer.
CHANGE THE LAMP
AFTER REPLACING LAMP,
RESET THE LAMP TIMER.
THE POWER WILL TURN OFF
AFTER ** hr. (*1)
Lamp usage time is approaching 2000 hours. (*2)
A lamp change within ** hours is recommended. When lamp usage reaches 2000 hours,
the power will automatically be turned OFF. Please change the lamp by referring to the
"Lamp" section of this manual. After you have changed the lamp, please be sure to reset
the lamp timer.
CHANGE THE LAMP
AFTER REPLACING LAMP,
RESET THE LAMP TIMER.
THE POWER WILL TURN OFF
AFTER 0 hr.
As lamp use has reached 2000 hours (*2), the power will soon be automatically turned
OFF.
Please immediately turn the power off, and change the lamp by referring to the "Lamp"
section of this manual. After you have changed the lamp, please be sure to reset the lamp
timer.
NO INPUT IS DETECTED
ON ***
There is no input signal.
Please con
fi
rm the signal input connection, and the status of the signal source.
SYNC IS OUT OF RANGE
ON *** fH *****kHz fV *****Hz
The horizontal or vertical wavelength of the inputted signal is outside of the response
parameters of this unit.
Please con
fi
rm the specs for this unit or the signal source specs.
CHECK THE AIR FLOW
The internal portion temperature is rising.
Please turn the power OFF, and allow the unit to cool down at least 20 minutes. After
having con
fi
rmed the following items, please turn the power ON again.
• Is there blockage of the air passage aperture?
• Is the air
fi
lter dirty?
• Does the peripheral temperature exceed 35°C?
CLEAN THE AIR FILTER
POWER OFF FIRST,
THEN CLEAN THE AIR FILTER.
AFTER CLEANING
THE AIR FILTER,
RESET THE FILTER TIMER.
A note of precaution when cleaning the air
fi
lter.
Please immediately turn the power OFF, and clean or change the air
fi
lter by referring
to the "Air Filter" section of this manual. After you have cleaned or changed the air
fi
lter,
please be sure to reset the
fi
lter timer.
If the same message is displayed after the treatment, please clean the transparent area
of
fi
lter cover and the dust-detecting window, according to the following "Caring Of The
Transparent Area Of Filter Cover and The Dust-detecting Window" .
Note:
(*1) • Although this message will be automatically disappeared after around 3 minutes, it will be reap-
peared every time the power is turned ON.
(*2) • Lamps have a finite product life. Lamps are characterized by the fact that, after long hours of usage, a
lamp will no longer light up, or the lamp will break or burst, etc. This unit is equipped with an automatic shut-
down function, such that the power will automatically be turned OFF when lamp usage time has reached 2,000
hours. Please be aware, however, that among lamp types, there are major differences in product lifetimes; a
lamp may thus fail to light even prior to the functioning of the automatic shut-down function of this unit.
Caring Of The Transparent Area Of Filter Cover And The Dust-detecting Window
The transparent area of filter cover and the dust-detecting window should be cleaned for normal operation of the
optical dust detecting system. Please pay attention not to remain fiber or fragment of cloth inside the duct.
1. Turn off the projector, and unplug the power cord.
2. After making sure that the projector has cooled
adequately, remove the
fi
lter cover.
Hold the release buttons of the
fi
lter cover, while
pulling up it.
3. Wipe the transparent area of the
fi
lter cover by using
a swab or a soft cloth.
4. Remove the air
fi
lter.
Hold the release buttons of the air
fi
lter, while pulling
down it.
5. Wipe the dust-detecting window by using a soft cloth.
6. Replace the air
fi
lter and
fi
lter cover.
Transparent area
Filter cover
(Rear side)
(Bottom side)
Dust-detecting
window
Filter cover
Release buttons
Air filter
Release buttons
Содержание Illumina PJ-TX10
Страница 52: ...PWB assembly MAIN 1 C10H ...
Страница 53: ...PWB assembly MAIN 2 C10H ...
Страница 54: ...PWB assembly MAIN 3 C10H ...
Страница 55: ...PWB assembly MAIN 4 C10H ...
Страница 56: ...PWB assembly MAIN 5 C10H ...
Страница 57: ...PWB assembly MAIN 6 C10H ...
Страница 58: ...PWB assembly MAIN 7 C10H ...
Страница 59: ...PWB assembly MAIN 8 C10H ...
Страница 60: ...PWB assembly MAIN 9 C10H ...
Страница 61: ...PWB assembly MAIN 10 C10H ...
Страница 62: ...MEMO MEMO ...
Страница 64: ...PJ TX10 YK No 0536E Digital Media Division QR57681 Printed in Japan JE ...