Adding and replacing hardware components
21
Hyper Scale-Out Platform Supporting and Troubleshooting
Step 3: Take the node out of maintenance mode
The longer a node is in maintenance mode, the greater the data on that node is at risk.
Take the node out of maintenance mode promptly after replacing the power supply.
Using the Management Console
1. Go to
Hardware
>
Nodes
.
2. On the
Nodes
page, point and click on the row in the list to select the node on which
you replaced the failed power supply.
3. Right-click to display the context menu and select
Unset
Maintenance
Mode
.
Using the Command Line Interface
1. Logged in to the CLI as
admin
or other administrative user.
2. Run the
hspadm
command to take the node out of maintenance mode. For example:
$ hspadm node edit --name Node007 --maintenance-mode n
Using the Management API
HTTP request syntax
POST https://<
cluster-ip
>:<
port
>/hspapi/nodes/<
node-id
>
and specify the following in the POST payload:
“maintenance-mode”: False