Test in resistance.
TOOL: Multimeter.
Test the resistance of the winding. The compressor is fault if the resistance of winding 0(short
circuit)or
∞
(
open circuit
)
Familiar error:
1
)
Compressor motor lock.
2
)
Discharge pressure value approaches static pressure value .
3
)
Compressor motor winding abnormality.
Notes
:
1
)
Don’t put a compressor on its side or turn over.
2) Please assembly the compressor in your air conditioner rapidly after removing the plugs. Don’t place
the comp. In air for along time.
3
)
Avoiding compressor running in reverse caused by connecting electrical wire incorrectly.
4
)
Warning! In case AC voltage is impressed to compressor, the compressor performance will below
because of its rotor magnetic force decreasing.
4. INDUCTANCE
Familiar error:
1
)
Sound abnormality
2
)
Insulation resistance disqualification.
5. STEP MOTOR
5
4
2
1
38