3. OPERATION
3-16
Notes about the case when link down is recorded in the log during OS startup.
While Windows® is starting, the following warnings may be displayed in the event log.
These warnings are recorded by the initialization process of the LAN driver at the startup of
Windows® and will not cause any problems in the system operation.
Event ID
Source
Type
Category
Description
27 e1qexpress
Warning None Intel(R)
82579LM
Gigabit Network Connection (*)
A network link has been lost.
27 e1rexpress
Warning None Intel(R)
82583V
Gigabit Network Connection (*)
A network link has been lost.
(*) How the name is displayed differs depending on the LAN adapter.
You can keep these warnings from being displayed in the event log by changing the LAN
adapter settings as follows.
Note that if you change the settings shown below, log entries such as LAN connection and
disconnection during system operation are also not recorded and that may make failure
analysis difficult when a problem occurs.
1. Execute steps 1 though 7 in “
Setting the network transfer speed” in “3.7 Setting Up
the LAN Interface”.
2. Click the
Advanced
tab. Select
Log Link State Event
. Select
Disabled
from the
Value
list.
Содержание HF-BX1000
Страница 1: ...BX 62 0001 01 ...
Страница 2: ...BX 62 0001 01 ...
Страница 61: ...This Page Intentionally Left Blank ...
Страница 70: ...3 OPERATION 3 9 5 Click ACPI x86 based PC Then click Microsoft ACPI Compliant System 6 Click PCI bus ...
Страница 79: ...3 OPERATION 3 18 2 In the Graphics and Media Control Panel window select Advanced Mode and click OK ...
Страница 85: ...This Page Intentionally Left Blank ...
Страница 155: ...This Page Intentionally Left Blank ...