--- 15 ---
Voltage
Current (A) Max.
110 V
5.9 A
9-6. Insulation Tests
After disassembly for repair servicing, the insulation resistance should be measured and the dielectric strength
test (withstand voltage test) performed.
Insulation resistance: 7 M
Ω
or greater
Dielectric strength: Normal after applying 4000 V for one minute.
9-7. No-load Current Value
After no-load operation for 30 minutes, the no-load current value should be as follows:
115 V
5.7 A
120 V
5.4 A
127 V
5.2 A
220 V
3.0 A
230 V
2.8 A
240 V
2.7 A
9-5. Wiring Diagram
Fig. 12