Procedure
Specify host group (CL1-C-0) and LU (0) to add an LU path to S-VOL
(0x4444).
raidcom add lun -port CL1-C-0 -lun_id 0 -ldev_id 0x4444 -IH1
Check command and output examples
Display the information about the LU paths that are defined in host group
(CL1-C-0).
raidcom get lun -port CL1-C-0 -fx -IH1
PORT GID HMD LUN NUM LDEV CM Serial# HMO_BITs
CL1-C 0 WIN 0 1 4444 - 322222
Updating the CCI configuration definition files
Before creating the GAD pair, you must update the CCI configuration
definition files on the primary and secondary systems to add the information
for the volumes that will become the P-VOL and S-VOL.
•
Shutting down CCI on page 4-42
•
Editing CCI configuration definition files on page 4-42
Configuration and pair management using CCI
4-41
Hitachi Virtual Storage Platform G1000 Global-Active Device User Guide
Содержание G1000
Страница 8: ...Index viii Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Страница 14: ...xiv Preface Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Страница 60: ...2 22 System requirements Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Страница 80: ...3 20 Planning for global active device Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Страница 128: ...4 48 Configuration and pair management using CCI Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Страница 238: ...9 18 Troubleshooting Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Страница 245: ...Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...