MAINTENANCE
7-41
Replace Filter --- every 500 hours
1. Unscrew cartridge filter (4) from the filter head, dis-
card the cartridge filter.
2. Fill the filter with oil. Apply a light even coat of lubricat-
ing oil to the gasket sealing surface prior to installing
the cartridge filter.
3. Position cartridge filter (4) to the filter head. Tighten by
hand until the seal touches the filter head, tighten an
additional three-fourths turn.
Clean Breather --- every 500 hours
Remove breather cap (5) and clean the element.
M18C-07-017
M18C-07-018
5
4