37
CP-X2511N(C15I-25N2) / CP-X3011N(C15I-30N2) / CP-X4011N(C15I-40N2) / CP-X2011N(C15-20N2) / ED-X45N(C15-20N2)
Preparation
1. Open the ADVANCED MENU and select OPTION
→
SERVICE
→
GHOST, and then press the
►
(right)
or the ENTER button to display the SERVICE_GOHST box.
2. While the RETURN is highlighted, operate the keypad or the remote control as follows. The DIGINAL
CONVERGENCE box will appear.
Keypad
Press the
▼
(down) button, and then hold the
▼
(down) button together with INPUT button for about
3seconds.
Remote control
Press the MAGNIFY OFF button, and then hold the MAGNIFY OFF button for about 3seconds.
3. Align the blue/red image with the green image using the HR, HB, VR and VB.
HR shifts the red image to the left/right.
HB shifts the blue image to the left/right.
VR shifts the red image upward/downward.
VB shifts the blue image upward/downward.
6-15 DIGITAL CONVERGENCE adjustment