Item

Specification

Operating temperature

10°C ~ 40°C
(50°F ~ 104°F)

Non-operating temperature range

-10°C ~ 50°C
(14°F ~ 122°F)

Operating relative humidity range

8% ~ 90% (non-condensing)

Non-operating relative humidity range

8% - 90% (non-condensing)

Environmental specification

Chapter 2: Hardware description

Service Processor 3 (SVP3) Technical Reference

14

Содержание E990

Страница 1: ...G F800 Hitachi Virtual Storage Platform N400 N600 N800 Service Processor 3 SVP3 Technical Reference This guide is intended for system administrators Hitachi Vantara representatives and authorized service providers and provides information about setting up configuring and maintaining both physical and virtual service processors MK 97HM85049 00 November 2020 ...

Страница 2: ...tinues to be held retrieved deleted or otherwise processed in accordance with relevant laws Notice on Export Controls The technical data and technology inherent in this Document may be subject to U S export control laws including the U S Export Administration Act and its associated regulations and may be subject to export or import regulations in other countries Reader agrees to comply strictly wi...

Страница 3: ...hased the product Recycling A nickel metal hydride battery is used in the Cache Backup Battery A nickel metal hydride battery is a resource that can be recycled When you want to replace the Cache Backup Battery call the service personnel They will dispose of it for you This nickel metal hydride battery which is designated as recycling product by a recycling promotion low must be recycled The mark ...

Страница 4: ...VP3 mounting considerations 15 Setting the voltage selector switch 15 Installing the inner rail extension 16 Installing the outer rails to the rack 17 Installing the SVP3 into the rack 18 Installing the front bezel 19 Connecting to the physical SVP3 20 Default IP address settings 20 Turning on power to the physical SVP3 21 Chapter 4 Installing the SVP software 22 Minimum requirements for installin...

Страница 5: ...Chapter 5 Registering the storage system on the Storage Device List 28 Adding the storage system to the Storage Device List 28 Contents Service Processor 3 SVP3 Technical Reference 5 ...

Страница 6: ...conventions This document uses the following typographic conventions Convention Description Bold Indicates text in a window including window titles menus menu options buttons fields and labels Example Click OK Indicates emphasized words in list items Italic Indicates a document title or emphasized words in text Indicates a variable which is a placeholder for actual text provided by the user or for...

Страница 7: ...uses the following icons to draw attention to information Icon Label Description Note Calls attention to important or additional information Tip Provides helpful information guidelines or suggestions for performing tasks more effectively Caution Warns the user of adverse conditions and or consequences for example disruptive operations data loss or a system crash WARNING Warns the user of a hazardo...

Страница 8: ...dent software vendors employees and prospects It is the destination to get answers discover insights and make connections Join the conversation today Go to community hitachivantara com register and complete your profile Comments Please send us your comments on this document to doc comments hitachivantara com Include the document title and number including the revision level for example 07 and refe...

Страница 9: ...s SVP3 installation The Hitachi Vantara provided SVP3 is a management server requiring a 1U of rack space Customers may also choose to provide their own physical or virtual server upon which the 64 bit software application may be installed For the latest SVP versions and platforms supported see https support hitachivantara com en user answers interoperability html Workflow of SVP3 installation 1 I...

Страница 10: ...ption 1 SVP3 drive Orange flashing LED indicates that the drive is busy 2 HUB reset button Restarts LAN2 LAN3 and LAN4 connected to the internal HUB The SVP3 will not restart and LAN1 will not be reset 3 MB reset button Restarts the SVP3 motherboard and LAN1 This will cause the Windows OS and all applications running on the operating system to reboot LAN2 LAN3 and LAN4 will not be reset 4 Power bu...

Страница 11: ...Connects to CTL1 5 LAN3 Connects to CTL2 6 LAN4 Connects to management network 7 Link Activity LED Orange Indicates link is up Orange flashing Indicates network activity 8 Speed LED Yellow Indicates communication speed of 1000 Mbps Green Indicates communication speed of 100 Mbps Off Indicates communication speed of 10 Mbps Back panel Chapter 2 Hardware description Service Processor 3 SVP3 Technica...

Страница 12: ... environment Caution The manual voltage selector switch must set to the correct voltage before installing the rail kit to the SVP3 The SVP3 has a tamper proof label covering the voltage selector switch which is set to the default 230V setting If this label has been removed you must confirm the switch setting before installing the rail kit Hardware specification Voltage selector switch Chapter 2 Ha...

Страница 13: ...erver Maximum temperature Up to 40 C 104 F The SVP3 is supported in high temperature environments Do not operate in any location with temperatures above 40 C 104 F Electrical specification Item Specification Rated AC voltage 100 120V 200 240V 50 50 Hz 2 1A 1 2A Power supply 200 W AC power supply Power supply safety EMC UL CSA UL cUL CB standard UL cUL 62368 IEC 62368 IEC 60950 1 CCC CCC GB4943 1 2...

Страница 14: ...operating temperature range 10 C 50 C 14 F 122 F Operating relative humidity range 8 90 non condensing Non operating relative humidity range 8 90 non condensing Environmental specification Chapter 2 Hardware description Service Processor 3 SVP3 Technical Reference 14 ...

Страница 15: ...the SVP3 in the top bay of the rack or as close to the top bay as possible Leaving approximately 25 inches in front of the rack to enable you to open the front bezel Leaving approximately 30 inches of clearance in the back of the rack to allow for sufficient airflow and ease in servicing Setting the voltage selector switch To prevent damage to the SVP3 power supply you must set the voltage selecto...

Страница 16: ...el covering the switch set to the default 230V setting If this label has been removed you must confirm the switch setting before installing the rail kit Installing the inner rail extension The SVP3 contains a rack rail assembly that must be separated into inner and outer rail extensions The inner rail extension attaches directly to the SVP3 while the outer rail extension attaches directly to the r...

Страница 17: ...y to the rack so the inner rail extension can be slid into place to secure the SVP3 to the rack Before you begin Confirm that the inner rail extension is installed Procedure 1 Using the directions on the rail orient the outer rail extension so the front of the rail faces the front of the rack 2 Adjust the short rail and long rail to the proper distance so that they fit snugly into the rack Install...

Страница 18: ...and screw Repeat step 3 through step 5 on both sides of the rack Installing the SVP3 into the rack After the inner rail extensions are attached to the SVP3 chassis and the outer rail extensions are attached to the rack the SVP3 can be installed in the rack Procedure 1 Align the SVP3 inner rails with the front of the horizontal outer rails on the rack 2 Slide the SVP3 inner rails into the outer rai...

Страница 19: ...d to the SVP3 and rack using rail brackets Before you begin Confirm the SVP3 is secure in the rack Procedure 1 Attach lock to right bracket using a screw and then set aside Installing the front bezel Chapter 3 Installing the SVP3 Service Processor 3 SVP3 Technical Reference 19 ...

Страница 20: ...ect to the LAN ports of the storage system s controller The LAN ports of the SVP3 are compatible with all network infrastructures The management console must be able to access the SVP3 Use Category 5 or higher Ethernet cables to connect the management console to the LAN port of the SVP3 Procedure 1 Connect the LAN1 port to a maintenance service PC 2 Connect the LAN4 port to a management console PC...

Страница 21: ...Do not use a power cable designed for another device Procedure 1 Insert the cable binder to the back of the SVP3 using the snap fastener 2 Pass the supplied power cable through the cable binder to fix it in place 3 Attach the power cable to the power socket on the rear panel of the SVP3 4 Plug the other end of the power cable into an AC power source Turning on power to the physical SVP3 Chapter 3 ...

Страница 22: ...em LAN connection one 1000Base T Windows 10 Enterprise 64 bit Note The customer supplied server running the Windows operating system cannot be used with the storage system if it belongs to different subnets and if a router or a firewall is filtering packets according to a defined condition There is not a limit for distance between the server running the SVP application and storage array being mana...

Страница 23: ...Music check Don t display this item Time settings Configure the SVP for Universal Coordinated Time Configure the SVP to not synchronize with an Internet time server Region settings Hide the language bar Using System Locale select the language for your region or preference and then restart the server In the Text Services and Input Language box check whether Japanese Japan appears under Installed se...

Страница 24: ...esktop and Remote Desktop RemoteFX for both Home Work Private and Public Internet Explorer settings Select Allow active content to run in files on My Computer Clear SSL 2 0 and select Use TLS 1 2 In the Turn on Suggested Sites window click No don t turn on and then click Next In the Choose your settings window click Use express settings and then click Finish Auto execute settings Turn off the Wind...

Страница 25: ... fPromptForPassword and then double click it and set the value to 1 Confirm that Hexadecimal is selected In the Edit menu click New DWORD 32 bit Value Type SecurityLayer Restart the server ICMP reply settings Click the following inbound rules and then right click and click Enable Rules File and Printer Sharing Echo Request ICMPv4 In Profile Domain File and Printer Sharing Echo Request ICMPv4 In Pr...

Страница 26: ...Tools IIS 6 Management Compatibility IIS 6 Scripting Tools IIS 6 WMI Compatibility IIS Metabase and IIS 6 configuration compatibility IIS Management Console IIS Management Scripts and Tools IIS Management Service Uncheck World Wide Web Services Installing the SVP software You install the SVP software from the SVP installation media for your storage system The installation media is part of the micr...

Страница 27: ...the SVP installation media folder 8 Right click Setup and choose Run as Administrator to launch the installation media 9 Click on Yes when prompted to allow the app to make changes to your device 10 In the Choose Server Language window select a language and click Next 11 Click Next to confirm setting 12 On the License Agreement window select I Accept and click Next 13 In the Choose Destination Loc...

Страница 28: ... installing the SVP software you must add the storage system to the Storage Device List Procedure 1 Log in to the Windows server with your SVP credentials and password 2 Double Click StorageDeviceList on the Windows desktop 3 Change the SVP IP address to 192 168 0 15 if not set by default and click Apply 4 Select the icon to open the Add System window Chapter 5 Registering the storage system on th...

Страница 29: ...to fill in the storage system information manually If using Auto Discovery skip to step 7 7 In the Add System window complete the fields and click Apply Field Description Software Selection Browse local hard drive for installation media files Adding the storage system to the Storage Device List Chapter 5 Registering the storage system on the Storage Device List Service Processor 3 SVP3 Technical R...

Страница 30: ... system up to 180 characters Permitted characters are one byte alphanumeric characters and symbols _ You cannot use one byte spaces Description Enter the description of the storage system up to 180 characters User Name Enter a user name Permitted characters are one byte alphanumeric characters and symbols _ The GUI includes a 256 character limit Password Enter a password The GUI includes a 256 cha...

Страница 31: ...s can log in to and start using the storage system the system administrator must complete the following setup and configuration tasks Configure the management client Configure the management software Configure the storage system Optional Set up SSL communications Set up the user accounts For details about these tasks and instructions for performing them see the System Administrator Guide for your ...

Страница 32: ...antara Corporate Headquarters 2535 Augustine Drive Santa Clara CA 95054 USA HitachiVantara com community HitachiVantara com Contact Information USA 1 800 446 0744 Global 1 858 547 4526 HitachiVantara com contact ...

Отзывы: