5. SPECIFICATIONS
Rated AC voltage
Rated AC current
Rated AC output
Max. output
Phase
Frequency
Engine
Model
Max. output
Fuel tank capacity
Recommended fuel
Oil capacity
Recommended oil
Spark plug
General
Starting system
Oil alert system
Auto idle system
Dry weight
[Including accessory]
Dimensions
[Including accessory]
E43
E 60
E 71
in. (mm)
L x W x H
Generator
Model
lb (kg)
V
Amp
VA
VA
Hz
bhp (kW)/3600r/min.
Gallons (Liters)
Quarts (Liters)
31.7/15.9
3800
4300
120/240
41.7/20.8
5000
6000
Single
60
GX240
GX340
GX390
8 (5.9)
11 (8.1)
13 (9.6)
5 (18.9)
Unleaded gasoline(86 octane or higher)
1.16 (1.1)
SAE 10W-30 API SJ or SL
BPR6ES (NGK) or W20EPR-U (DENSO)
Recoil
Provided
Provided
42.3 x 29.4 x 29.0 (1075 x 746 x 737)
26.0 x 21.7 x 20.7 (660 x 550 x 525)
157 (71)
(198 (90))
181 (82)
(223 (101))
201 (91)
(243 (110))
50.0/25.0
6000
7100
6. CAPACITY OF GENERATOR
6-1. Selection of Proper Generator
Select the proper generator as follows according to the power consumption, output and the like of the AC
electrical equipment to be used.
(1) When the power consumption of the electrical equipment is known
When the power consumption of the electrical equipment is known, calculate the necessary output of the
generator (VA) according to the formula shown in the table below. When the sum of the calculated "necessary
output of the generator (VA)" is equal to or less than the rated AC output of the generator, the generator can
be used continuously.
1.0
Electrical equipment
Power factor
Electric power tools
(Commutator motors)
Bulbs, electric heaters, etc.
General-purpose motors
(Induction motors)
0.8 to 0.95
0.4 to 0.75
Necessary output of the generator (VA)
Power consumption of the
electrical equipment (W)
Power factor