--- 32 ---
8-5. Insulation Tests
On completion of reassembly after repair, measure the insulation resistance and conduct the dielectric strength
test.
Insulation resistance: 7 M
Ω
or more with DC 500 V Megohm Tester
Dielectric strength: AC 2500 V/1minute, with no abnormalities
8-6. No-Load Current Value
After no-load operation for 30 minutes, the no-load current value should be as follows.
Voltage (V)
3.0
Current (A) Max.
120
Содержание D 10VF
Страница 39: ... 36 602 612 602 605 613 603 604 605 606 607 608 609 610 611 8 01 D 13VF ...
Страница 43: ... 40 ALTERNATIVE PARTS ITEM NO CODE NO DESCTIPTION REMARKS NO USED D 13VF Printed in Japan 010821N 8 01 ...
Страница 45: ... 42 8 01 D 13VG 602 612 602 613 605 603 604 605 606 606 609 610 611 608 ...
Страница 49: ... 46 ITEM NO CODE NO DESCTIPTION REMARKS NO USED D 13VG Printed in Japan 010821N 8 01 ...
Страница 50: ......
Страница 88: ...ELECTRIC TOOL PARTS LIST LIST NO DRILL Model D 10VF 2000 12 20 E1 0194 ...
Страница 91: ... ALTERNATIVE PARTS ITEM NO CODE NO DESCRIPTION REMARKS NO USED PARTS Printed in Japan 001220N 12 00 D 10VF ...
Страница 92: ...ELECTRIC TOOL PARTS LIST LIST NO DRILL Model D 10VG 2000 12 20 E1 0195 ...
Страница 95: ... ALTERNATIVE PARTS ITEM NO CODE NO DESCRIPTION REMARKS NO USED PARTS Printed in Japan 001220N 12 00 D 10VG ...
Страница 96: ...ELECTRIC TOOL PARTS LIST LIST NO DRILL Model D 13VF 2000 12 20 E1 0196 ...
Страница 97: ...D 13VF 12 00 ...
Страница 100: ...ELECTRIC TOOL PARTS LIST LIST NO DRILL Model D 13VG 2000 12 20 E1 0197 ...
Страница 101: ...D 13VG 12 00 ...
Страница 104: ......