6
English
●
Regarding the temperatures and charging time of the
battery.
The temperatures and charging time will become as
shown in
Table 2
.
Table 2
Charger
Battery
UC18YKSL
Charging voltage
V
14.4
–
18
Weight
kg
0.35
Temperatures at which the battery
can be recharged
0
o
C
–
50
o
C
Charging time (At 20
o
C)
BSL1815 Approx. 40 min.
Number of battery cells
5
NOTE
The recharging time may vary according to the ambient
temperature and power source voltage.
CAUTION
When the battery charger has been continuously used,
the battery charger will be heated, thus constituting
the cause of the failures. Once the charging has been
completed, give 15 minutes rest until the next charging.
4. Disconnect the charger’s power cord from the
receptacle.
5. Hold the charger
fi
rmly and pull out the battery.
NOTE
Be sure to pull out the battery from the charger after use,
and then keep it.
CAUTION
○
If the battery is charged while it is heated because it has
been left for a long time in a location subject to direct
sunlight or because the battery has just been used, the
pilot lamp of the charger lights for 1 second, does not
light for 0.5 seconds (o
ff
for 0.5 seconds). In such a case,
fi
rst let the battery cool, then start charging.
○
When the pilot lamp
fl
ickers (at 0.2-second intervals),
check for and take out any foreign objects in the charger’s
battery connector. If there are no foreign objects, it is
probable that the battery or charger is malfunctioning.
Take it to your authorized Service Center.
○
Since the built-in micro computer takes about 3 seconds to
con
fi
rm that the battery being charged with charger is taken
out, wait for a minimum of 3 seconds before reinserting it
to continue charging. If the battery is reinserted within 3
seconds, the battery may not be properly charged.
Table 1
Indications of the pilot lamp
Pilot lamp
(red)
Before
charging
Blinks
Lights for 0.5 seconds. Does not light for 0.5
seconds. (o
ff
for 0.5 seconds)
While charging Lights
Lights continuously
Charging
complete
Blinks
Lights for 0.5 seconds. Does not light for 0.5
seconds. (o
ff
for 0.5 seconds)
Overheat
standby
Blinks
Lights for 1 second. Does not light for 0.5
seconds. (o
ff
for 0.5 seconds)
Battery overheated.
Unable to charge.
(Charging will
commence when
battery cools)
Charging
impossible
Flickers
Lights for 0.1 seconds. Does not light for 0.1
seconds. (o
ff
for 0.1 seconds)
Malfunction in the
battery or the charger
○
If the pilot lamp does not blink in red (every second)
even though the charger cord is connected to the power,
it indicates that the protection circuit of the charger may
be activated.
Remove the cord or plug from the power and then
connect it again after 30 seconds or so. If this does
not cause the pilot lamp to blink in red (every second),
please take the charger to the Hitachi Authorized Service
Center.
MOUNTING AND OPERATION
Action
Figure
Page
Attaching the dust collection adapter
(optional accessories)
2
183
Mounting the blade
3
183
Dismounting the blade
4
183
Cutting metallic materials
5
183
Plunge cutting in lumber
6
184
Plunge cutting in materials other
than lumber
7
184
Angular cutting
8
184
Removing and inserting the battery
9
185
Charging
10
185
Switch operation
11
185
Adjusting the orbital operation
12
185
Selecting accessories
―
186
SELECTION OF BLADES
To ensure maximum operating e
ffi
ciency and results, it is
very important to select the appropriate blade best suited to
the type and thickness of the material to be cut. The blade
number is engraved in the vicinity of the mounting portion
of each blade. Select appropriate blades by referring to
Table 3
.
0000Book̲CJ18DGL.indb 6
0000Book̲CJ18DGL.indb 6
2016/01/27 10:33:22
2016/01/27 10:33:22