23
English
TROUBLESHOOTING
Use the inspections in the table below if the tool does not
operate normally. If this does not remedy the problem,
consult your dealer or the Hitachi Authorized Service Center.
Symptom
Possible cause
Remedy
Charger
The Charge lamp does
not go on.
The power plug is not connected to an
AC outlet.
Connect the power plug to an AC outlet.
The battery is not properly connected to
the charger.
Insert the battery so that it is properly
seated in the charger.
The battery or charger electrodes are
soiled.
Use a cotton swab or other tool to clean
the electrodes.
The battery is extremely hot.
Allow the battery to properly cool before
charging.
Tool
Does not operate.
The rechargeable battery is depleted.
Charge the rechargeable battery.
The rechargeable battery has not been
properly installed.
Remove the rechargeable battery from
the battery compartment in the tool and
check for and remove any foreign matter.
Also check the battery electrodes for
soiling, water or other foreign matter. Use
a cotton swab for cleaning. Make sure
that the rechargeable battery is pressed
in until it clicks into place.
The power has not been turned on.
Press the power button on the housing
to start the tool. This tool comes with an
auto power o
ff
function. The power is
automatically turned o
ff
if nobody pulls
the lever during a one minute period after
power on. To turn the tool on again, press
the power button a second time.
Pressing the power button a second time
turns the power o
ff
.
The main pipe is not fully extended
(The red light blinks rapidly) (CG36DAL,
CG36DAL (L) only)
To prevent accidents due to malfunction,
the tool is designed so that the motor will
not operate unless the main pipe is fully
extended.
Extend the main pipe fully until it clicks.
The lock lever was not pressed when the
lever was pulled back.
To prevent accidents from incorrect
operation, the lock lever must be pressed
while the lever is pulled back to start the
motor.
Hold the handle from above and press
the lock lever while pulling the handle.
The tool pulls in large volumes of grass
that are caught between the cover and
the nylon head, the tool is overloaded.
This is the e
ff
ect of a function that
protects the rechargeable battery by
turning o
ff
the motor when the tool is
exposed to an excessive load. Turn o
ff
the tool and remove the cause of the
overload. Press the power button once
again to continue operation.
Goes on, but soon
stops.
The rechargeable battery power is low.
Charge the rechargeable battery.
The rechargeable battery is overheated.
Stop using the rechargeable battery,
remove it from the tool and let it cool in
a well-ventilated location not exposed to
sunlight.
The locking lever is not locked, causing
the main pipe to shorten up during work.
(The red light blinks rapidly) (CG36DAL,
CG36DAL (L) only)
Lock the locking lever.
000Book̲CG36DL̲WE.indb 23
000Book̲CG36DL̲WE.indb 23
2013/08/27 17:09:57
2013/08/27 17:09:57
Содержание CD 36DAL
Страница 122: ...122 000Book CG36DL WE indb 122 000Book CG36DL WE indb 122 2013 08 27 17 10 03 2013 08 27 17 10 03 ...
Страница 124: ...124 1 2 3 4 5 000Book CG36DL WE indb 124 000Book CG36DL WE indb 124 2013 08 27 17 10 04 2013 08 27 17 10 04 ...
Страница 126: ...126 000Book CG36DL WE indb 126 000Book CG36DL WE indb 126 2013 08 27 17 10 04 2013 08 27 17 10 04 ...