--- 49 ---
a Ink line is not right
angle.
b Laser marker accuracy
is not adjusted
properly.
c Product accuracy is
not good.
------
0.2/100
(Figs. 70 and 71)
• Make a correct ink line again.
• Readjust the accuracy of the
laser marker. (Refer to "11-9.
Adjustment of Laser Marker
Accuracy".)
• Readjust the accuracy of the
product and the laser marker.
Item
Phenomenon
Cause
Factory
standard
Inspection, repair or
adjustment
8
Laser line does not
match the ink line.
Fig. 70
Fig. 71
a Laser marker is
horizontally deviated
from the saw blade.
b Laser marker accuracy
is not adjusted
properly.
------
------
• Adjust the position of the laser
line. (Refer to "8-1. Position
Adjustment of Laser Line".)
• Same as item 8-(b).
9
Laser line does not
match the cutting
position.
a Improper wiring
b Monitor failure
c Monitor ass'y failure
d Switching power
supply failure
------
------
------
------
• Check the wiring.
• Replace the Monitor Ass'y
[118].
• Check the Monitor Ass'y [118]
for conductivity.
• Replace the Monitor Ass'y
[118].
• Check the Switching Power
Supply [220] for conductivity.
• Replace the Switching Power
Supply [220].
10
Digital display does not
indicate anything.
(Model C 12LDH)