29
Parameter
Normal
ADJ. DISP
77
77
INT START
03
03
DEMO WAIT
2F
2F
V. SQUEEZE
FO
F1
INT STEP 1
02
02
INT STEP 2
06
06
INT DELAY
01
01
INT BAR
30
30
MGF STEP 1
00
00
MGF STEP 2
06
06
MGD DELAY
01
01
MGF BAR
1B
1B
SENSOR CK
00
00
PORT 0
00
00
PORT 1
01
01
PORT 2
02
02
PORT 3
03
03
PORT 4
04
04
PORT 5
05
05
PORT 6
06
06
PORT 7
07
07
AD LEVEL
03
03
CENT BAL
00
00
E. DISPLAY
00
00
E. ADJ. TIMS
60
60
E. AD LEVEL
03
05
E. AD NOISE
0A
0A
PHASE MOT
60
60
H. BLK-RV
05
03
H. BLK-GV
01
01
H. BLK-BV
05
03
H. BLK-H
00
00
PON DELAY
0C
0C
IR-CODE
00
00
INITIAL 50
9E
9E
MGF 50
96
96
CENTER 50
FE
FE
STAT 50
FE
FE
DYNA 50
9F
9F
1080i
Through
2.12.1 MAGIC FOCUS Character Set-Up
This instruction should be applied when a new DCU
is being replaced.
Adjustment Preparation
(1) Receive NTSC RF or video signal.
(2) With Power off, PRESS and HOLD the SERVICE
ONLY button on CONVER/FOCUS PWB, then press
the Power On/Off, when picture appeares release
SERVICE ONLY switch. (Internal crosshatch is
displayed without conv. correction data.)
Adjustment Procedure
(1) Press FREEZE key on R/C. (One additional line
appears near the top and near the bottom.)
(2) Press PIPCH key, then ADJ. PARAMETER mode is
displayed as following.
(3) Press
or
key to change the ADJ. DISP. data.
(4) Press CURSOR
to access DCU parameter.
Change the data as shown on Table 1,2 OR 3, DCU
Parameter.
ADJ. PARAMETER
ROM WRITE?
ADJ. DISP. : 77
SEL. STAT. : 00
DEMO.WAIT : 2f
NORMAL MODE
TABLE 1. - DCU PARAMETER (DP15K)
Parameter
Normal
ADJ. DISP
77
77
DEMO WAIT
2F
2F
INT. START
03
03
V. SQUEEZE
F0
F1
INT STEP1
02
02
INT STEP2
06
06
INT BAR
30
30
INT DELAY
01
01
MGF STEP1
00
00
MGF STEP2
06
06
MGF BAR
1B
1B
MGF DELAY
01
01
SENSOR CK
00
00
PORT 0
00
00
PORT 1
01
01
PORT 2
02
02
PORT 3
03
03
PORT 4
04
04
PORT 5
05
05
PORT 6
06
06
PORT 7
07
07
AD LEVEL
03
03
CENT. BAL.
01
01
E. DISPLAY
00
00
E. ADJTIMS
60
60
E. ADLEVEL
05
05
E. ADNOISE
0A
0A
PHASE MOT
60
60
H. BLK-RV
06
03
H. BLK-GV
01
01
H. BLK-BV
06
03
H. BLK-H
00
00
PON DELAY
0C
0C
IR-CODE
00
00
INITIAL 50
9E
9E
MGF 50
96
96
CENTER 50
FE
FE
STAT 50
FE
FE
DYNA 50
9F
9F
1080i
Through
TABLE 2. - DCU PARAMETER (DP15H)
Parameter
Normal
ADJ. DISP
77
77
DEMO WAIT
2F
2F
INT. START
03
03
V. SQUEEZE
F0
F1
INT STEP1
02
02
INT STEP2
06
06
INT BAR
2A
2A
INT DELAY
01
01
MGF STEP1
00
00
MGF STEP2
06
06
MGF BAR
1B
1B
MGF DELAY
01
01
SENSOR CK
00
00
PORT 0
00
00
PORT 1
01
01
PORT 2
02
02
PORT 3
03
03
PORT 4
04
04
PORT 5
05
05
PORT 6
06
06
PORT 7
07
07
AD LEVEL
03
03
CENT. BAL.
00
00
E. DISPLAY
00
00
E. ADJTIMS
60
60
E. ADLEVEL
05
05
E. ADNOISE
0A
0A
PHASE MOT
60
60
H. BLK-RV
06
03
H. BLK-GV
01
01
H. BLK-BV
06
03
H. BLK-H
00
00
PON DELAY
0C
0C
IR-CODE
00
00
INITIAL 50
9E
9E
MGF 50
96
96
CENTER 50
FE
FE
STAT 50
FE
FE
DYNA 50
9F
9F
1080i
Through
TABLE 3. - DCU PARAMETER (DP15J)