23
Important:
High Voltage adjustment should
NOT be adjusted in field. This is
adjusted at factory using precise
loads and should NOT
be
readjusted.
1.4 High Voltage Adjustment (should NOT be
readjusted in field).
Adjustment preparation
(1) Connect High Voltage meter to FBT High Voltage
output. Connect GND of High Voltage meter to CPT
GND or FBT GND.
(2) Check that High Voltage adjustment VR (RH17) is
set to mechanical center. (located behind FBT on
DEFLECTION PWB).
(3) Receive circle pattern signal.
(4) VIDEO control should be reset.
Adjustment procedure
(1) Adjust High Voltage to following spec. by turning VR
RH17 slowly. ADJ. SPEC = 30.2 ± 0.2kV
(2) After adjustment, fix VR RH17 with Silicone glue
(KE40RTV).
2. FINAL ASSEMBLY ADJUSTMENT
2.1 Cut Off Adjustment
Adjustment preparation
(1) Adjust screen VR’s on Focus Pack fully
counterclockwise.
(2) Adjust Focus VR’s on Focus Pack fully
clockwise.
(3) Set video conditions to factory preset.
(4) The vertical incident illumination on the screen
should be 20 lux or less (room should be dark).
!
CONV.
HEATSINK.
DEFLECTION PWB.
RH17
High Voltage Adjustment VR.
T702
(FBT)
Adjustment procedure
(1) Press and hold INPUT key on control panel and
then POWER ON to access I
2
C adjustment
mode.
(2) Choose “SERVICE” item from I
2
C adjustment
menu by pressing CURSOR
.
(3) Screen VR should be turned clockwise gradually
and set so that retrace line begins to appear.
(4) Return to “NORMAL” mode by CURSOR
again.
(5) Adjust Focus VR’s so that focus is even all
around screen.
2.2
DCU Phase Data Setting
Adjustment preparation
(1) Cut off adjustment should be finished.
(2) Set video conditions to factory preset.
Adjustment procedure
(1) Receive any NTSC signal.
(2) Push “SERVICE ONLY” SW on CONV. FOCUS
PWB. (Enter to DCU ADJ. mode).
(3) Push HELP key on R/C. (Green cross hatch is
displayed).
Then push EXIT key on R/C. (Character pattern
is displayed. This is the PHASE setting mode).
(4) Set PH-H phase data as shown below by using
4 and 6 key on R/C.
(5) Set PH-V phase data as shown below by using
2 and 5 key on R/C.
(6) Set CR-H phase data as shown below by using
CURSOR
and
key on R/C.
(7) Set CR-V phase data as shown below by using
CURSOR
and
key on R/C.
(8) Push HELP key on R/C to exit from the PHASE
mode.
(9) Push PIP MODE key 2 times on R/C to write the
phase data to memory.
(10) When Green dots are displayed, push MUTE
key to return to DCU ADJ. mode.
(11) Push “SERVICE ONLY” SW to return to RF or
VIDEO mode.
(12) Receive any 1080i signal (Input to Component
video terminal). Select “Aspect 5” on SET-UP,
PICTURE FORMAT of OSD MENU.
(13) Repeat steps (2) ˜(11) above.
NORMAL MODE
TH01
1080i THROUGH MODE
1080i THROUGH MODE
NORMAL MODE
PHASE MODE
PH-H :BF
PH-V: 07
CR-H: 4C
CR-V: 0C
PHASE MODE
PH-H: BF
PH-V: 07
CR-H: 4C
CR-V: 0C
Static Focus VR
R
G
B
R
G
B
Screen VR
Focus VR
Screen VR
FOCUS PACK