MAINTENANCE
7-84
Replacing Fuses
--- as necessary
If any electrical part or component ceases to function, check
its fuse first. The fuse box is located behind the operator’s seat.
f
NOTE:
One spare fuse for each capacity is provided in the fuse box.
A special tool for fuse removal is also provided in the fuse
box.
10- CONTROLLER
5 A
20- OPTION3
5 A
9- BACK UP
10 A
19- HORN
10 A
8- ECM
30 A
18- IDLE STOP
5 A
7- START
5 A
17- POWER ON
5 A
6- OPTION2
20 A
16- GLOW RELAY
5 A
5- OPTION1
5 A
15- AUXILIARY
10 A
4- SOLENOID
20 A
14- MONITOR
5 A
3- HEATER
20 A
13- LIGHTER
10 A
2- WIPER
10 A
12- RADIO
5 A
1- LAMP
20 A
11- FUEL PUMP
5 A
1
11
4
14
7
17
2
12
5
15
8
18
3
13
6
16
9
19
10
20
Tool
Spare Fuses
M1GR-01-003
MDCN-01-010
Содержание 090001
Страница 4: ......
Страница 9: ...CONTENTS Bucket Teeth Transverse Type Pin Used Type 13 18 INDEX 14 1 ...
Страница 10: ...CONTENTS MEMO ...
Страница 14: ...MACHINE NUMBERS 4 MEMO ...
Страница 64: ...MEMO SAFETY SIGNS S 50 ...
Страница 198: ...OPERATOR S STATION 1 134 MEMO ...
Страница 200: ...BREAK IN 2 2 MEMO ...
Страница 212: ...OPERATING THE ENGINE 3 12 MEMO ...
Страница 266: ...OPERATING THE MACHINE 5 46 MEMO ...
Страница 392: ...MAINTENANCE 7 118 13 Cab mounting nut 14 Cover mounting bolt M1U1 07 026 MDCN 07 073 Anchor Bolts MDCN 07 022 ...
Страница 398: ...MAINTENANCE 7 124 MEMO ...
Страница 399: ...8 1 HYDRAULIC CIRCUIT AND ELECTRICAL CIRCUIT Hydraulic Circuit MDAA 08 001 ...
Страница 402: ...MAINTENANCE UNDER SPECIAL ENVIRONMENTAL CONDITIONS 9 2 MEMO ...
Страница 404: ...STORAGE 10 2 MEMO ...