6
䡬
Get rid of the staples, fragments, adhesives, wood
chips, etc., jammed in the guide groove using a slotted
head screwdriver or the like. (
Fig. 10
)
Fig. 10
䡬
At the time of assembly, make sure that the push lever
is properly inserted into the blade guide’s guiding
section. (
Fig. 11
)
Fig. 11
䡬
After assembly, check and make certain that the push
lever can move up and down smoothly.
NOTE:
䡬
If the driver blade’s tip is worn out, staples tend to get
jammed. Request repair service if the staples get
jammed frequently.
2. Check on mounting screws for each part
At regular intervals check every part for loose
mounting screws and whether or not there are any
air leaks. Retighten any loose screws. Operating the
equipment with loose screws untightened will incur
a hazard.
3. Inspecting the push lever
Check if the push lever can slide smoothly. (
Fig. 16
)
Clean up the sliding area of the push lever and use the
provided oil for lubrication from time to time.
Lubrication enables smooth sliding and
simultaneously serves to prevent the formation of
rust.
Fig. 12
4. Inspecting the magazine
䡬
Clean up the magazine from time to time.
Remove the dust, wood chips, etc., accumulated in it.
䡬
Lubricate the staple feeder’s spring sometimes.
Pull the staple feeder backward, and lubricate the
spring from the back in a state where the staple feeder
is hooked onto the magazine’s groove. (
Fig. 13
)
Fig. 13
5. Storing
䡬
When not in use for an extended period, apply a thin
coat of the lubricant to the steel parts to avoid rust.
䡬
Do not store the Stapler in a cold weather environment.
Keep the Stapler in a warm area.
䡬
When not in use, the Stapler should be stored in a
warm and dry place.
Keep out of reach of children.
COMPRESSOR
CAUTION:
When the maximum, operating pressure of the air
compressor exceeds 8.3 bar (120 psi.), be sure to
provide a reducing valve between the air compressor
and stapler. Then, adjust the air pressure within the
operating range of 4.9 – 8.3 bar (70 – 120 psi.). If the air
set is installed, lubrication is also possible, thus
providing additional convenience.
OILER-FILTER-REDUCING VALVE (Air Set)
So that the equipment can be operated under an optimum
condition to ensure extended service life, it is
recommended to use an oiler filter reducing valve. Please
limit the length of the hose between the unit and the air set
to within 10m when using.
Fig. 14
Guide Groove
Push Lever
Slotted-head
Screwdriver
Guiding Section
Push Lever
Blade Guide
M 6
×
6 hexagon
socket bolt
Lubricate
Push Lever
Oiler
(provided oil)
Spring
Staple Feeder
Magazine
Groove
Filter
Oiler
Stapler
Side
Compressor
Side
➡
➡
Reducing Valve