background image

 

Will the refrigerator for repair, must first pull out the power plug, assure maintenance safety

   

3

Prevent to electric shock: 

 

Usually for repair shall first will cut off power supply. If must be energized check circuit, should be 

careful to get an electric shock, do not touch charged area. Maintenance if discover the wire aging, 

should change in time

   

4

The correct use of spare parts: 

 

Maintenance of the need to replace parts of the same model, must be the parts (repairing parts 

listed in the table), do not get optional change other models or other brand of spare parts, the more 

don't maintain spare parts, avoid p other accidents

 

5

The correct use of maintenance tools: 

 

Maintenance must use the proper maintenance tools. Improper use tools may cause bad contact   

or fastening rickety and accidents

 

6

Wire connection: 

 

Reconnecting first must weld, or use connected terminals, and insulation tape sealing, ensure 

good contacts

 

7

Insulation testing: 

 

after the maintenance assembly,    the insulation resistance testing must use a multimeter to 

confirm insulation resistance, 

up to 1 M Ω above, can electrify operation

 

8

Grounding check: 

 

After repair must use a multimeter fortesting grounding resistance , confirm for the grounding 

resistance is less than 0.15 Ω,namely,grounding is good.if    grounding bad or incomplete, should be 

handled in time, ensure complete, good, reliable grounding

 

9

Pay attention to the child: 

 

The refrigerator for repair, attention shall be paid to prevent children from near, lest produce risk

 

10

Clean: 

After the maintenance the refrigerator is necessary to clean, and inform the users

 

 

 

 

 

 

 

Содержание RS-09DC4S Series

Страница 1: ...REFRIGERATOR Service manual MODEL RS 09DC4S BD 65 NOTE This is a basic model the shape and specification of refrigerator is subject to change ...

Страница 2: ...PARTS INENTIFICATION NOTE This figure is only a sketch Of the Refrigerator and the actual Products may differ from it CIRCUIT DIAGRAM COOLING DIAGRAM ...

Страница 3: ...e guide for Disassembly Common parts of Refrigerator The instruction of replacing thermostat The location of the thermostat remove screws of top cover Capillary Compressor Dry filter Condenser Evaporator ...

Страница 4: ...ire Take out the thermostat The instruction of replacing PTC Starting relay and Overload protector Take down Spring tap and Cover Unplug the connecting wire Take out the PTC Starting relay and Overload protector Door Reversal ...

Страница 5: ...TROUBLESHOOTING The common problem judging method ...

Страница 6: ...opriate 4 2 Is there multi moisture food and too close to the back wall of the refrigerator 4 3 Is the ambient temperature too low 4 4 Is the electric parts on good condition specially the thermostat wich will cause the unit non stopping Abnormal noise 5 1 Is the refrigerator stably placed 5 2 Does the refrigerator bump other objects 5 3 Whether the internal accessory of the refrigerator is in the...

Страница 7: ...nit will work not well Phenomenon of failure a higher pressure of liquid cycle system than norm b higher temperature of condenser c larger electric current of compressor d there maybe ice on the suction tube e when gas is too much some gas liquid might goes back into compressor compressor will be damaged by liquid First stop unit for several minutes and then open charging tube discharge all of gas...

Страница 8: ...int is there 2 There is some thing that blocked the liquid cycle system A Ice blocking Sometime because unknown reason water comes into liquid cycle system the capillary will be blocked by water after unit runs for period of time Phenomenon of failure The unit works well in the inception after period of time the ice appears in the capillary and becomes more and more till blocks the hole of capilla...

Страница 9: ... Please put the food properly 5 Wind door is broken Replace wind door 6 Fan motor is broken Replace fan motor Note Before doing these operations above disconnect the main power supply Failure to do so could result in electrical shock or personal injury In case of any detailed technical information please check with the technical specifications announcements of Maintenance operation safety In order...

Страница 10: ...oper maintenance tools Improper use tools may cause bad contact or fastening rickety and accidents 6 Wire connection Reconnecting first must weld or use connected terminals and insulation tape sealing ensure good contacts 7 Insulation testing after the maintenance assembly the insulation resistance testing must use a multimeter to confirm insulation resistance up to 1 M Ω above can electrify opera...