6
Installing your new appliance
VENTILATION OF APPLIANCE
Leveling Of Appliance
Electrical Connection
WARNING
This appliance must be grounded. The man-
ufacturer declines any liability should these
safety measures not be observed.
Cabinetleg
600mm
595mm
862mm
1164mm
≥50mm
≥50mm
≥50mm
Before using the appliance for the first time, you
should be informed of the following tips.
In order to improve efficiency of the cooling
system and save energy, it is necessary to maintain
good ventilation around the appliance for the
dissipation of heat.
For this reason, sufficient clear space should be
available around the product.
Suggest:
It is advisable for there to be at least
50 mm of space from the back to the wall, at
least 100 mm from its top, and at least 50mm
from its side to the wall. As shown in the
following diagrams.
Note:
·Avoid locating the appliance in damp
areas .Too much moisture in the air will cause
frost to form quickly on the evaporator.·Keep
the appliance out of direct sunlight, rain or
frost. Position the product away from heat
sources such as stoves, fires or heaters.
≥100mm
·Position your appliance in a dry place to avoid
high moisture.
The appliance should be level in order to eliminate
vibration. We recommend that you level the appliance
by the following steps.
1. Put the refrigerator into the right place.
2. Turn the adjustable feet (with your fingers or a suitable
screw driver) until they touch the floor.
3. Tilt back the top backwards for about 10-15mm or
1°by turn the adjustable feet. This will allow the doors to
self-close providing a consistent closed seal.
Cabinetleg
Caution! Any electrical work required to install this
appliance should be carried out by a qualified
person or authorized service technician.