![Hisense H60STEB Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/hisense/h60steb/h60steb_user-and-installation-manual_2138506015.webp)
Electrical connection
o Before connecting the appliance, make sure that the supply voltage marked on the rating
plate corresponds with your mains supply voltage.
The installation must be carried out by a suitably qualified person, in accordance with the
current regulations.
o
WARNING
:
THIS APPLIANCE MUST BE EARTHED.
o The hob must be wired into a double phase power supply, witch 2 Live and Neutral, having
3 mm contact separation and placed in an easily accessible position adjacent to the
appliance. The spur outlet must still be accessible even when your cooktop is located in its
housing.
YOUR HOB IS INTENDED FOR FITTED AND PERMANENT INSTALLATION.
safty,the Hob must be earthed reliably.
Please remove this sentence
for 220-240V earthed one-phase
connection,bridges connect N1-N2
terminals and L1-L2 terminals, safety wire
to
For 380-415V 2N~ earthed two- phase
connection,bridges connect N1-N2
terminals ,the safety wire to
For 380-415V 2N~ earthed two-phase
connection,the safety wire to
H05W-F3G2,5
H05W-F4G2,5
H05W-F5G1,5
11
L-N:220-240V~
3x2.5
mm
²
L1-L2:380-415 2N~
4x2.5
mm
²
L1-L2:380-415 2N~
5x1.5
mm
²
N
N1
N2
L2
L1
L
N
N1
N2
L2
L1
L1
L2
N1
N1
N2
L2
L1
L1
L2
N2