Normal range of C&S : About 10-27
Ω
Normal range of S&M : About 20-50
Ω
If the test result is not in this range then it means the inner coil has some problem and the compressor
can not work properly.
Compressor Protector test
——
Use a multi-meter to test the resistance between the two end as the pic show :
If there show 000 or almost 0 then it is OK.
If there is no response then it is broken.
Compressor PTC starter test
——
Use a multi-meter to test the resistance between the two end as the pic show :
If there show the number is between About 9-25
Ω
then it is OK.
If there show 000 or no response then it is broken.