8
System Overview Ground Water with
Intermediate Heat Exchanger System
Name
Description
Location
Name
Description
Location
P2
Outdoor side water pump
External
OT
Outdoor temperature
sensor
Internal
P3
Ground water pump
External
FL
Particle filter
External
BK
Brine tank/expansion
tank
External
SAK
Safety valve
External
FW
Water flow switch
External
FI
filter
External
DP
Intermediate heat
exchanger
External
Principle of Operation:
An intermediate heat exchanger (DP) should be installed to prevent ground water
damaging or contaminating the unit’s internal heat exchanger. A plate heat exchanger
that is able to be cleaned is recommended for this situation that can be disassembled
for cleaning and repair or any damage plates can be replaced. Anti-freezing
measurement must be adopted to protect the ground water circuit.
Systems Overview (Outdoor side)