![Hirschmann RSP 20 Скачать руководство пользователя страница 27](http://html1.mh-extra.com/html/hirschmann/rsp-20/rsp-20_user-manual_2138133027.webp)
Installation RSP 20/25/30/35
Release 15 12/2017
27
1.6
Display elements
After the supply voltage is set up, the software starts and initializes itself.
Afterwards, the device performs a self-test. During this process, various
LEDs light up.
1.6.1
Device state
These LEDs provide information about conditions which affect the operation
of the whole device.
Applies to software releases
before
02.0.00:
LED
Display
Color Activity
Meaning
Power Supply voltage
—
none
Supply voltage is too low
yellow Lights up
Device variants with redundant power
supply:
Supply voltage 1
or
2 is on
flashes 4 times
a period
Software update is running. Maintain the
power supply.
green Lights up
Device variants with redundant power
supply:
Supply voltages 1
and
2 are on
Device variants with single power supply:
Supply voltage is on
RM
Ring Manager
—
none
No redundancy configured
green Lights up
Redundancy exists
Flashes 1 time
a period
Device is reporting an incorrect
configuration of the RM function
yellow Lights up
No redundancy exists
ACA
Storage medium
ACA31
—
none
ACA storage medium not connected
green Lights up
ACA storage medium connected
Flashes 3
times a period
Device writes to/reads from the storage
medium
yellow Lights up
ACA storage medium inoperative
LED
Display
Color Activity
Meaning
Status Device Status
—
none
Device is starting and/or is not ready for
operation
green Lights up
Device is ready for operation.
Characteristics can be configured
red
Lights up
Device is inoperative
Flashes 1 time
a period
The boot parameters used when the
device has been started differ from the
boot parameters saved.
Start the device again.
Status
RM
ACA
Power