26
Installation OCTOPUS OS20/OS24 Unmanaged
Release 08 07/2015
To protect the exposed uninstalled contacts of the components from dirt,
connect the individual system components in a dry and clean working area.
When you are selecting the installation location, make sure you observe
the climatic threshold values specified in the technical data.
Prevent heat from the surroundings from affecting the device.
Applies to devices featuring supply voltage with the characteristic value F:
Take care that the temperature of the device base plate remains under
194 °F (90 °C) during operation.
You achieve this, for example, by means of one of the following
measures:
You make sure that the operating voltage of the device is at least 20 V.
You limit the total PoE output to a maximum of 47 W.
You limit the ambient temperature to a maximum of 149 °F (65 °C).
You install the device on a 1.62 ft
2
(0.15 m
2
) metal plate to which you
will connect no other heat sources.
Prepare the drill holes at the installation point.
Mount the device on a level surface with four M5 screws.
2.3.1
Grounding the device
The device is grounded via the separate ground screw.
The overall shield of a connected shielded twisted-pair cable is connected to
the metal housing as a conductor.
Applies to devices featuring supply voltage with the characteristic
value A:
Use the M3 screw for the function ground.
Applies to devices featuring supply voltage with characteristic value F and
N:
Use the M4 screw for the protective ground.
Use toothed washers to ensure good electrical conductivity at the
connection.
2.4
Connecting the ferrite
Applies to devices featuring supply voltage with the characteristic value F:
To adhere to EMC conformity, you connect the ferrite supplied to the voltage
input via the power supply cable.