background image

Hirschmann Automation and Control GmbH
Stuttgarter Straße 45-51
D-72654 Neckartenzlingen
Germany
Tel.: +49-1805-14-1538
Fax: +49-7127-14-1551
E-Mail: [email protected]
Internet: http://www.hirschmann-ac.com

Printed in Germany
Subject to alterations

Position

Attribute

Ident.

Feature

1 to 4

Product

MM20

Media module 10/100 Mbit/s (standard)

MM21

Media module 10/100 Mbit/s (realtime)

MM22

Media module 10/100 Mbit/s (Power over Ethernet)

MM30

Media module 1000 Mbit/s (standard)

5

- (hyphen)

6 and 7 

1st port (media/connector)

T1

Twisted pair (TX) / RJ45

T5

Twisted pair (TX) / M12

M2

Multimode FX DSC (only 100 Mbit/s)

M3

Multimode FX MTRJ (only 100 Mbit/s)

M4

Multimode FX ST (only 100 Mbit/s)

S2

Singlemode FX DSC (only 100 Mbit/s)

S4

Singlemode FX ST (only 100 Mbit/s)

L2

Singlemode longhaul FX DSC (only 100 Mbit/s)

G2 

Singlemode longhaul FX DSC 200km (only 100 Mbit/s)

F4

Multimode FL ST (only 10 Mbit/s)

P4

POF FX ST (only 100 Mbit/s)

O7

Combo port gigabit Ethernet (SFP only 1000 Mbit/s)

A8

AUI Sub-D

Z6

Fiber optic / SFP slot (100 Mbit/s)

8 and 9

2nd port (media/connector)

...

See position 6 and 7

10 and 11 3rd port (media/connector)

...

See position 6 and 7

99

Empty

12 and 13 4th port (media/connector)

...

See position 6 and 7

99

Empty

14

Temperature range

S

Standard 0 °C to +60 °C

T

Extended -40 °C to +70 °C

E

Extended -40 °C to +70 °C & Conformal Coating

15

Specifications

A

CE, UL 508, ISA 12.12.01 (UL 1604)

H

A plus GL, IEC 61850, IEEE 1613 substation, EN 50121-4 railway (along track) 

B

H plus ATEX100a

Содержание MM2-2FXM3/2TX1

Страница 1: ...24 4 MS4128 5 MICE switch basic module for installing media modules MICE allows you to construct switched Industrial ETHERNET networks that con form to the IEEE 802 and 802 3u standard using copper wires or optical fibers in a bus or ring topology In the User manual Installation User manual Basic configuration User manual Redundancy configuration Reference manual Web based Interface Reference manu...

Страница 2: ... sensitive to electrostatic fields These components can be easily destroyed or have their lives shortened by an electrical field or by a discharge caused by touching the contacts You can find more informationen about devices vulnerable to electrostatic fields in DIN EN 61340 5 1 2001 08 and DIN EN 61340 5 2 2002 01 Recycling Note After its use this product has to be processed as electronic scrap a...

Страница 3: ...oltage 䡺 Make sure that the external power supply unit being used for providing the PoE voltage meets among other things the following requirements Isolation requirements in compliance with IEEE 802 3af electrical strength of the 48V output to rest of the world 2250 V DC for 1 min Output power 100 W Current limiting 2 A Power supply unit and PoE media module form a Limited Power Sour ce in complia...

Страница 4: ... dB km 10 MHz km P4 MM HCS 650 nm 200 230 µm 0 7 0 dB 0 140 m 10 dB km 17 MHz km G2 LH 1550 nm 9 125 µm 14 47 dB 67 176 km 0 25 dB km 19 ps nm km F O port 100BASE FX SFP Fiberoptic Fast ETHERNET Transceiver Product code Wave length Fiber System attenuation Expansion Fiber data M FAST SFP MM LC EEC MM 1310 nm 50 125 µm 0 11 dB 0 5 km 1 0 dB km 800 MHz km MM LC EEC MM 1310 nm 62 5 125 µm 0 8 dB 0 4 ...

Страница 5: ...on Time Protocol MICE 2000 media modules Module type AUI port TP ports F O port F O port F O port F O port F O port Supported since 10 100 multimode multimode multimode singlemode singlemode MICE SW release 10 Mbit s POF 100 Mbit s 1300 nm 1550 nm PowerMS20 100 Mbit s 100 Mbit s 100 Mbit s MICE MICE MS30 MM2 4TX1 EEC 4 RJ45 1 0 1 0 1 0 MM2 2FLM4 2 ST 1 0 1 0 1 0 MM2 2FXP4 2 ST 4 0 1 0 1 0 MM2 4FXM...

Страница 6: ...0 1 0 Table 3 Number of media connectors each MICE 4000 media module kind of connector and necessary software Open variant media modules Module type TP ports SFP ports Supported since 10 100 1000 alternativ zu TP Ports MICE SW release alternatively to TP ports Power MS20 MICE MICE MS30 MM20 MM21 MM30 0 to 4 ports media and connector at your option see chapter 8 Open Variant 2 0 MM22 T1T1T1T1 4 por...

Страница 7: ...3 8 W 13 0 Btu IT h see chapter 8 see chapter 8 product code chap 8 MM20 1 TX 3 FX Ports 5 3 W 18 1 Btu IT h see chapter 8 see chapter 8 product code chap 8 MM20 0 TX 4 FX Ports 6 8 W 23 2 Btu IT h see chapter 8 see chapter 8 product code chap 8 MM20 A8A89999 3 4 W 11 6 Btu IT h see chapter 8 see chapter 8 product code chap 8 MM20 F4F4F4F4 5 0 W 17 1 Btu IT h see chapter 8 see chapter 8 product co...

Страница 8: ...ly 100 Mbit s M4 Multimode FX ST only 100 Mbit s S2 Singlemode FX DSC only 100 Mbit s S4 Singlemode FX ST only 100 Mbit s L2 Singlemode longhaul FX DSC only 100 Mbit s G2 Singlemode longhaul FX DSC 200km only 100 Mbit s F4 Multimode FL ST only 10 Mbit s P4 POF FX ST only 100 Mbit s O7 Combo port gigabit Ethernet SFP only 1000 Mbit s A8 AUI Sub D Z6 Fiber optic SFP slot 100 Mbit s 8 and 9 2nd port ...

Отзывы: