![Hirschmann MACH104-20TX-F Series Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/hirschmann/mach104-20tx-f-series/mach104-20tx-f-series_user-manual_2138025031.webp)
MACH104
Release 09/09
31
3
Technical data
General technical data
EMC and immunity
Dimensions
W x H x D
MACH104-...
448 mm x 44 mm x 345 mm (without brackets)
Weight
MACH104-20TX-F
MACH104-20TX-FR
MACH104-20TX-F-4PoE
4.2 kg
4.4 kg
4.6 kg
Power supply
Rated voltage
Rated frequency
Rated power range
100 - 240 VAC
47 - 63 Hz
0.4 - 0.2 A
1.1 - 0.5 A for devices with PoE
Overload current
protection at input
Non-replaceable fuse
Activation current
typ. <40 A at 265 V AC and cold start
“FAULT”
signal contact
Switching current
max. 1 A, SELV
Switching voltage
max. 60 V DC or max. 30 V AC, SELV
Environment
Storage temperature
(ambient air temperature)
Humidity
Air pressure (in opera-
tion)
-20 °C to +85 °C
10% to 95% (non-condensing)
Up to 2000 m (795 hPa), higher altitudes on
request
Operating temper-
ature
0 °C to +50 °C
Pollution degree
2
Protection classes Laser protection
Protection class
Class 1 according to EN 60825-1 (2001)
IP 30
EMC interference
immunity
EN 61000-4-2
Electrostatic discharge
Contact discharge
Air discharge
4 kV
8 kV
EN 61000-4-3
Electromagnetic field
80 - 2,700 MHz
10 V/m
EN 61000-4-4
Fast transients (burst)
- Power line
- Data line
2 kV
4 kV
EN 61000-4-5
Voltage surges
- Power line, line/line:
- Power line, line/earth
- Data line
1 kV
2 kV
4 kV
EN 61000-4-6
Line-conducted interference voltages
150 kHz - 80 MHz
10 V
EMC emitted inter-
ference
EN 55022
Class A
Yes
FCC 47 CFR Part 15 Class A
Yes