Device state
These LEDs provide information about conditions which affect the opera-
tion of the whole device.
If the manual adjustment is active on the “FAULT” signal contact, then the
detected error display is independent of the setting of the signal contact.
P - Power
(green/yellow LED)
Glowing green
MACH104-20TX-F, MACH104-20TX-F-4PoE:
Supply voltage is on.
MACH104-20TX-FR:
Supply voltages 1 and 2 are on.
Glowing yellow
MACH104-20TX-FR: Supply voltage 1 or 2 is on.
Not glowing
MACH104-20TX-F, MACH104-20TX-F-4PoE:
Supply voltage is below minimum value.
MACH104-20TX-FR:
Supply voltages 1 and 2 are below minimum value.
RM - Ring Manager (green/yellow LED)
Glowing green
RM function active, redundant port disabled
Glowing yellow
RM function active, redundant port enabled
Not glowing
RM function not active
Flashing green
Incorrect configuration of the HIPER-Ring (e.g. the ring is not
connected to the ring port).
Sb StandBy - stand-by mode (green LED)
Glowing green
Stand-by mode enabled.
Not glowing
No stand-by mode.
FAULT - signal contact
(red LED)
Glowing red
Signal contact 1 is open, i.e. it is reporting an error.
Not glowing
Signal contact 1 is closed, i.e. it is not reporting an error.
RM and Stand-by - display saving processes of the AutoConfiguration Adapter (ACA)
Flashing alternately
Error during saving process.
LEDs flash synchronously, two
times a second
Loading configuration from the ACA.
LEDs flash synchronously,
once a second
Saving the configuration in the ACA.