Installation MACH1000
Release 06 03/2021
35
Applies to software release 06.0.00 and higher:
Applies to software releases previous to 06.0.00:
Applies to software release 06.0.00 and higher:
If the manual setting is active on the signal contact, then the error display is
independent of the setting of the signal contact.
1.5.2
Port status
The green and yellow LEDs at the individual port display port-related
information. During the boot phase, these LEDs are used to display the
status of the boot procedure.
LED
Display
Color Activity
Meaning
FAULT Signal contact 1 red
lights up
The signal contact is open - it is reporting a
detected error.
none
The signal contact is closed, it is
not
reporting
any detected errors.
Duplicate IP
detection
red
flashes 4 ×
a period
Reports an IP conflict.
LED Display
Color Activity
Meaning
R1
Signal contact 1 yellow lights up
The signal contact is closed in manual operation.
none
The signal contact is open in manual operation.
R2
Signal contact 2 yellow lights up
The signal contact is closed in manual operation.
none
The signal contact is open in manual operation.
LED
Display
Color
Activity
Meaning
R1
Signal contact 1 yellow lights up
The signal contact is open.
none
The signal contact is closed.
R2
Signal contact 2 yellow lights up
The signal contact is open.
none
The signal contact is closed.
LS - Data, Link Status (1 green/yellow LED or 1 green and 1 yellow LED)
Not glowing
No valid connection.
Glowing green
Valid connection.
Flashing green (1 × a period)
Port is switched to stand-by.
Flashing green (3 × a period)
Port is disabled.
Flashing yellow
Data reception.
Содержание MACH1000 Series