![Hirschmann GREYHOUND GMM 40 Скачать руководство пользователя страница 61](http://html1.mh-extra.com/html/hirschmann/greyhound-gmm-40/greyhound-gmm-40_user-manual_2138093061.webp)
Installation GREYHOUND Switch
Release 01 04/2016
61
7.1.3
Media modules
Dimensions
See “Dimension drawings” on page 62.
Weight of media
modules
GMM20-MMMMMMMM
16.72 oz (520 g)
additional 150 g for media modules with
temperature range characteristic value
T and E
GMM20-NNNNNNNN
GMM20-VVVVVVVV
GMM20-UUUUUUUU
GMM30-MMMMTTTT
19.4 oz (550 g)
GMM30-NNNNTTTT
GMM30-VVVVTTTT
GMM30-UUUUTTTT
GMM40-TTTTTTTT
17.28 oz (490 g)
GMM40-OOOOOOOO
22.93 oz (650 g)
GMM40-OOOOTTTT
19.05 oz (540 g)
GMM32-MMMMTTTT
19.75 oz (560 g)
GMM32-NNNNTTTT
GMM32-VVVVTTTT
GMM32-UUUUTTTT
GMM42-OOOOTTTT
19.4 oz (550 g)
GMM42-TTTTTTTT
17.99 oz (510 g)
Climatic conditions
during operation
Ambient temperature
Devices with operating temperature
characteristic value S (standard):
+32 °F ... +140 °F (0 °C ... +60 °C)
a
a. Hirschmann recommends to use SFP transceivers with the "EEC" extension.
Devices with operating temperature
characteristic value E and T (extended)
−
40 °F ... +158 °F (
−
40 °C ... +70 °C)
b
−
40 °F ... +185 °F (
−
40 °C ... +85 °C)
for 16 hours (tested in accordance with
IEC 60068-2-2)
b. Use SFP transceivers with the “EEC” extension only, otherwise the standard temperature
range applies.
Humidity
5 % ... 95 %
(non-condensing)
Air pressure
at least 600 hPa (+13123 ft; +4000 m)
maximum 1060 hPa (
−
1312 ft;
−
400 m)
Climatic conditions
during storage
Ambient temperature
−
40 °F ... +185 °F (
−
40 °C ... +85 °C)
Humidity
5 % ... 95 %
(non-condensing)
Air pressure
at least 600 hPa (+13123 ft; +4000 m)
maximum 1060 hPa (
−
1312 ft;
−
400 m)
Pollution degree
2
Protection classes
Laser protection
Class 1 in compliance with IEC 60825-1