Hirschmann 943 633-001 Скачать руководство пользователя страница 15

7

Notes on CE identification

The Twisted Pair Industrial Hubs
for ISO/DIN Rail comply with the
regulations of the following
European directive:

89/336/EEC
Council Directive on the harmo-
nisation of the legal regulations
of member states on electroma-
gnetic compatibility (amended
by Directives 91/263/EEC,
92/31/EEC and 93/68/EEC).

Area used

Requirements for
emitted interference

interference immunity

Residential

EN 50081-1: 1992

EN 50082-1: 1992

Industrial

EN 50081-2: 1993

EN 50082-2: 1995

The product can be used in the residenti-
al sphere (residential sphere, business
and trade sphere and small companies)
and in the industrial sphere.

The precondition for compliance with
EMC limit values is strict adherence to
the construction guidelines specified in
this description and operating instruc-
tions and in the “Ethernet manual“.

The EU declaration of conformity is kept
available for the responsible authorities
in accordance with the above-mentioned
EU directives at:

Richard Hirschmann GmbH & Co.
Network Systems Division
Stuttgarter Straße 45-51
D-72654 Neckartenzlingen
Tel+49-7127-14-1538

F/O line length (example)

50/125 µm fiber

max. 2.600 m 

8530 ft

62,5/125 µm fiber

max. 3.100 m

10170 ft

Scope of delivery

Rail Transceiver RT1-TP/FL (Media converter)

terminal block for supply voltage
description and operating instructions

Order number

Rail Transceiver RT1-TP/FL

943 633-001

Accessories

Ethernet manual

943 320-011

Содержание 943 633-001

Страница 1: ...ten ange schlossen werden ber LWL ist der Anschlu eines weiteren Endger tes oder einer optischen Netzkomponente RH1 TP FL ECFL2 Mini OTDE etc m glich Kontroll LEDs f r Power Datenempfang Link Status M...

Страница 2: ...chkeit in die ser Betriebsanleitung nicht jede nur erdenkliche Problemstellung im Zusam menhang mit dem Einsatz dieses Ger tes beschrieben werden kann Sollten Sie weitere Informationen ben tigen oder...

Страница 3: ...t das angeschlossene TP Segment arbeitet ordnungsgem leuchtet nicht RT1 TP FL empf ngt keine Idle Signale vom TP Segment der zugeordnete TP Port ist nicht ange schlossen das angeschlossene Ger t ist a...

Страница 4: ...ich der fehlerhafte Linkstatus des TP Ports Port 1 w hrend Schalter LA1 auf ON steht der fehlerhafte Linkstatus des LWL Ports Port 2 w hrend Schalter LA2 auf ON steht Die Meldung des Linkstatus kann p...

Страница 5: ...baren Twisted Pair Leitungen ist elek trisch leitend mit dem Geh use verbun den Abb 6 Montage des RT1 TP FL Twisted Pair Leitung DTE Trans ceiver RH1 TP FL RH1 TP FL RH1 TP FL RT1 TP FL RT1 TP FL Aut...

Страница 6: ...x H x T 40 mm x 134 mm x 80 mm Masse 520 g Umgebungstemperatur 0 C bis 60 C Lagerungstemperatur 40 C bis 80 C Luftfeuchtigkeit 10 bis 90 nicht kondensierend Schutzklasse IP 30 Funkst rgrad EN 55022 C...

Страница 7: ...e sowie Kleinbetriebe sowie im Industriebereich Voraussetzung f r die Einhaltung der EMV Grenzwerte ist die strikte Einhal tung der in dieser Beschreibung und Betriebsanleitung angegebenen Aufbau rich...

Страница 8: ...0395950010898000 Richard Hirschmann GmbH Co Produktbereich Netzwerktechnik Stuttgarter Stra e 45 51 D 72654 Neckartenzlingen Telefon 07127 14 1538 Printed in Germany Subject to alterations Notizen Not...

Страница 9: ...k components can be attached via fiber optic an additional device or an optical network component RH1 TP FL ECFL2 Mini OTDE can be attached Monitoring LEDs for Power RxData Link status Link status mon...

Страница 10: ...ld furthermore point out that for reasons of simplicity these operating instructions cannot describe every conceivable problem associated with the use of this equipment Should you requi re further inf...

Страница 11: ...roperly lit not RT1 TP FL not reveiving idle signals from TP seg ment the assigned TP port is not attached the attached device is switched off the TP line is interrup ted or short circuited RT1 TP FL...

Страница 12: ...e setting of DIP switch LA1 is ON the faulty link status of the F O port port 2 if the setting of DIP switch LA2 is ON The indication of the link state might be masked on a port by port basis using th...

Страница 13: ...nd of the twisted pair lines which can be connected is electrically connected to the housing Fig 6 Assembling RT1 TP FL Twisted pair line DTE Trans ceiver RH1 TP FL RH1 TP FL RH1 TP FL RT1 TP FL RT1 T...

Страница 14: ...age temperature 40 C to 80 C 40 F to 176 F Humidity 10 to 90 non condensing Protection class IP 30 Radio interference level EN 55022 Class B Interference immunity EN 50082 2 Network size Transition TP...

Страница 15: ...in the industrial sphere The precondition for compliance with EMC limit values is strict adherence to the construction guidelines specified in this description and operating instruc tions and in the E...

Страница 16: ...0395950010898000 Richard Hirschmann GmbH Co Produktbereich Netzwerktechnik Stuttgarter Stra e 45 51 D 72654 Neckartenzlingen Telefon 07127 14 1538 Printed in Germany Subject to alterations Notizen Not...

Отзывы: