![HIQUEL SLS-500 Master Controller Скачать руководство пользователя страница 72](http://html1.mh-extra.com/html/hiquel/sls-500-master-controller/sls-500-master-controller_software-manual_2137777072.webp)
HIQUEL
HIQUEL
HIQUEL
HIQUEL
SLS-500-Configurator
www.hiquel.com
72
Example:
+
+
L1.AI1
L1.AI1
50.0
50.0
MyMemory
MyMemory
The value 50.0 will be added to the current value of analogue
input L1.AI1. The result will be saved to MyMemory.
Analogue operator: Subtraction
Symbol:
-
-
Data type: In1,In2
Analogue
Out
Analogue
Function:
This function subtracts the value of one analogue input from
another analogue output and saves the result to output Out.
Example:
L1.AI1
L1.AI1
MyMemory
MyMemory
-
-
L1.AI2
L1.AI2
Analogue value L1.AI2 is subtracted from analogue value
L1.Al1. The result will be saved to MyMemory.