![HIQUEL SLS-500 Master Controller Скачать руководство пользователя страница 165](http://html1.mh-extra.com/html/hiquel/sls-500-master-controller/sls-500-master-controller_software-manual_2137777165.webp)
HIQUEL
HIQUEL
HIQUEL
HIQUEL
SLS-500-Configurator
www.hiquel.com
165
Data type: Show
Bit
Time
Analogue
Default
Analogue
Value
Analogue
Item
Text
Ready
Bit
Ok
Bit
Cancel
Bit
Time
Bit
#1-#15
Bit
Function:
with this function, if input Show has a rising edge the terminal
will display the stored text. Additionally you can set a display
time in seconds at input
Time
. If this time runs out, output
Time
will be activated. If the input stays unconnected, the time
function will be ignored. Output
Ready
will be active when the
complete screen set-up is finished. If the user presses the OK
button, output
OK
will be activated. If the user presses the
Cancel button, output
Cancel
will be activated.
The entered message will be build up. The displayed entry
corresponds to input
Default
. If this input is unconnected, the
first entry will always be displayed. If you choose an entry and
press OK, output
Value
will output the number of the chosen
entry. Output
Item
will output the entry text and the