Functions
Control Function
Power switch
【
POWER
】
Button switch. The LED lights when the power is on. *
1
The power is automatically turned off when the instrument is not operated (or torque
load is less than 10) for a period of 10 minutes.
Reset switch
【
RESET
】
Used to return the display to zero or print out data.
Display
Measuring
unit
display
Unit selector
【
UNIT
】
Switches between one of the following combinations of torque measurement units,
depending on which combination the purchaser ordered: N
•
m
↔
lbf
•
in, N
•
m
↔
N
•
cm,
N
•
m
↔
kgf
•
cm
Measuring mode selector
PEAK: Freezes display at peak torque value. (Press reset to cancel)
【
MODE
】
TRACK: Displays current torque value.
F.PEAK: Freezes display at first peak torque value.
AC connector
For battery charger.
Analog data output
Port for analog voltage data output.
【
ANALOG OUT
】
Digital data output
Press reset to output measurement data. This functions makes it possible to use the
【
DATA OUT
】
instrument in statistical process control systems.*
2
DIP switch
For setting auto reset timer and turning data output on ("P.ON" LED indicates "on"
setting).
Torque set switch A
【
SET
】
Sets maximum torque load at which warning tone will sound.
Memory function toggle switch The LED lights when the memory function is on.
【
M_SET
】
Torque set switch B
【▲】
Sets the torque level at which the warning tone sounds.
Max load warning tone
The LED lights when this function is on.
on/off switch
【
BZ
】
Memory clear switch
【
M_CR
】
Deletes data in memory.
Average measurement
When average measurement mode is on, the LED lights and the torque measure-
mode switch
【
AVE
】
ment average values are displayed.
Support arm (comes with Model HDP-50/HDP-100)
Use the support arm when measured torque is too high for the operator to control
without assistance. It makes stable measurement possible with merely a light touch.
*
1
Please push the power switch and detach it immediately until a buzzersounds.
*
2
Statistical Process Control (SPC) uses statistical techniques to monitor variations in manufacturing processes for use in quality control.
Support arm
Model N
•
m N
•
cm
HDP-5
0.000
0.0
HDP-50
0.00
0
HDP-100
0.00
0
Part No.
TCH-MULTI
1 pc
(for AC100-240V, A plug)
PSE, cUL, UL
JAPAN, U.S.A, Canada,
Mexico, Taiwan, Thailand,
Philippines
Part No.
TCH-MULTI-CN
1 pc
(for AC100-240V, A plug)
CCC
China
Part No.
TCH-MULTI-CE
1 pc
(for AC100-240V, A plug)
CE
Vietnam, Indonesia, India,
Singapore, Malaysia, Korea,
Hong Kong, U.K., Ireland,
South America, The Middle
East, New Zealand
Part No.
TCH-EU
1 pc
(for AC100-240V, C plug)
CE
Europe (except U.K.,
Ireland)
• Battery Charger
- 4 -
Содержание HDP-100
Страница 14: ......
Страница 15: ......
Страница 16: ...1 16 5 Akiyama Matsudo City Chiba Pref Japan TEL 81 Japan 47 392 2001 FAX 81 Japan 47 392 7773 ...