87
Message List
8.8 Message List
Message
[ ]: Omissible
Data
[ ]: Omissible,
( ): Response data
Description
Reference
*
IDN?
(<Manufacturer
name>,<Model
name>,<Serial
No.>,<Software version>)
Queries the device ID (ID code).
*
RST
Initializes the device.
*
TST?
(<PASS/FAIL>)
Initiates a self-test and queries the
result.
*
TRG
Trigger
*
OPC
Wait for the present operation to
complete and then set OPC of SESR.
*
OPC?
(1)
Wait for the present operation to
complete and then respond with
ASCII “1” .
*
WAI
Wait for the present operation to
complete.
*
CLS
Clears the Event Register and the
Status Byte Register.
*
ESE
0 to 255
Sets the Standard Event Status
Enable Register (SESER).
*
ESE?
(0 to 255)
Queries the Standard Event Status
Enable Register (SESER).
*
ESR?
(0 to 255)
Queries the Standard Event Status
Register (SESR).
*
SRE
0 to 255
Sets the Service Request Enable
Register (SRER).
*
SRE?
(0 to 255)
Queries the Service Request Enable
Register (SRER).
*
STB?
(0 to 255)
Queries the Status Byte Register.
:STATus:OPERation:CONDition?
(0 to 65535)
Queries the Condition Register of the
Standard Operation Register Group.
:STATus:OPERation[:EVENt]?
(0 to 65535)
Queries the Event Register of the
Standard Operation Register Group.
:STATus:OPERation:ENABle
0 to 65535
Sets the Enable Register of the
Standard Operation Register Group.
:STATus:OPERation:ENABle?
(0 to 65535)
Queries the Enable Register of the
Standard Operation Register Group.
:STATus:QUEStionable:CONDition?
(0 to 65535)
Queries the Condition Register of the
Status Query Register Group.
:STATus:QUEStionable[:EVENt]?
(0 to 65535)
Queries the Event Register of the
Status Query Register Group
:STATus:QUEStionable:ENABle
0 to 65535
Sets the Enable Register of the Status
Query Register Group.
:STATus:QUEStionable:ENABle?
(0 to 65535)
Queries the Enable Register of the
Status Query Register Group.
:STATus:PRESet
Initialize the device.
(Same setting as
*
RST
)
8
Communication Function
Содержание SW1001
Страница 2: ......
Страница 42: ...38 Precautions for Measurement...
Страница 48: ...44 Resetting Scan Operation...
Страница 50: ...46 Checking the Device Status...
Страница 52: ...48 Initialization Settings...
Страница 118: ...114 Sample Programs 3 Select File Save All 4 Check the save location and click Save as...
Страница 156: ...152 Outline Drawings 12 4 Outline Drawings SW1001 Unit mm Tolerance 0 2...
Страница 157: ...153 Outline Drawings SW1002 Unit mm Tolerance 0 2 12 Appendix...
Страница 158: ...154 Outline Drawings...
Страница 161: ...16 01 EN...
Страница 162: ......
Страница 163: ......
Страница 164: ......