Easy-to-use RESISTANCE METER

suits both manual operation and integration with automatic lines

RM3544

High-intuitive advanced functionality

RM3544

RM3545

RM3544

1

2

3

4

Guard terminals

Minimize the effects of external noise on measurements.

* GUARD terminal is the shield potential.

  This terminal is not for guarding network resistance measurements.

1

Simple control over basic settings

Range and measurement speed can be controlled directly.

2

LED COMPARATOR ATTACHMENT (Option)

The  LED  Comparator  Attachment 

indicates judgment results with 

green  and  red  LEDs,  eliminating 

the need to look at the instrument’s 

screen  and  increasing  work  effi-

ciency. Since the lamps do not light 

up when the measurement leads are 

open, the attachment can also be 

used to verify the connection status.

Red light

HI/LO state

Green light

IN state

3

High-volume, user-selectable judgment tones

The RM3544 indicates results with a high-volume judgment tone of 85 dB 

or greater to ensure it is audible near noisy machinery. 

Both the RM3545 and RM3544 feature user-selectable judgment tones so 

workers don’t confuse judgment results on lines where multiple resistance 

meters are being used.

4

Functionality for saving and loading panels

The RM3545 (RM3544) can save and load up to 30* (10) sets of range, 

comparator, and other settings.  Naming each set of panel data lets you 

make setup changes among production lots and lines smoothly and ef-

fortlessly.

*When using the multiplexer terminals, up to 8.

5

Material-and temperature-independent 

temperature correction function

The temperature correction function can be used to convert resistance 

values that vary with the ambient temperature to a reference value at a 

reference temperature using the Temperature Sensor Z2001 and a user-

specified resistance temperature coefficient.

6

Comparator Function

The comparator function compares measured values to a previously 

set reference value or range and then displays and outputs the judg-

ment result. The RM3545 and RM3544

-01

 can also output this infor-

mation using EXT I/O.

8

Scaling

The scaling function can be used to convert resistance values into physical 

properties such as length. 

 

Conversion formula : Rs = A × R + B

7

A, B : Constants, R : Measurement value

Rs : Resistance value

5

6

7

8

Intuitive, graphical LCD

High-precision specs in a compact package

Compared to the previous model (HIOKI 3540), the RM3544/RM3544

-01

 

take up approximately 25% less installation space. 

This space-saving design frees up space in front of the instrument and 

lets you build compact production lines.

 Footprint of just 215 × 166 mm

Содержание RM3544

Страница 1: ...tion 0 01 LP 0 01m Basic accuracy 0 02 No of display digits Max 4 5 Max resolution 1 Featuring super high accuracy and multi channel capabilities 20 channels with 4 terminal measurement RESISTANCE MET...

Страница 2: ...or both manual operation and integration with automatic lines Max measurable current 1A Max resolution 0 01 Basic accuracy 0 006 Resistance measurement Max measurable current 1mA Max Open circuit volt...

Страница 3: ...on Pictured Back of the RM3545 02 with two Z3003 units optional feature installed Insert up to two Z3003 units into the slots on the back of the instrument Multi point measurement with the Multiplexer...

Страница 4: ...immediately after startup without any warm up or zero adjustment When performing measurement with the RM3545 in a temperature and humidity environ ment that satisfies the guaranteed accuracy condition...

Страница 5: ...act resistance indi cates an error Time R RM3545 Logger Auto scanning and step scanning When using the Multiplexer Unit Z3003 to perform scanning measure ment you can select either step scanning or au...

Страница 6: ...or saving and loading panels The RM3545 RM3544 can save and load up to 30 10 sets of range comparator and other settings Naming each set of panel data lets you make setup changes among production lots...

Страница 7: ...d to toggle the input signal polar ity between NPN sink output support and PNP source output support settings depending on the PLC common polarity EXT I O Input and Output Circuits EXT I O polarity Se...

Страница 8: ...ternal I O comparator BCD BIN function 3 3 3 Communication interfaces RS 232C Printer USB 3 3 3 GP IB N A 3 N A Multiplexer scanner function N A N A 3 Max 20 channels When using 4 terminal measurement...

Страница 9: ...rminal settings Front terminals MUX multiplexer When using the MUX setting the measurement leads cannot be connected to the front measurement terminals Support unit Z3003 Number of channels that can b...

Страница 10: ...0 m 0 008 0 005 0 007 0 002 0 007 0 001 1mA 20V 100k 120 000 0 k 100 m 0 008 0 005 0 007 0 002 0 007 0 001 100 A 1000k 1200 000 k 1 0 015 0 005 0 008 0 002 0 008 0 001 10 A 10M 12 000 00 M 10 0 030 0...

Страница 11: ...k 0 020 0 010 0 020 0 007 1mA 30k 35 000 k 0 020 0 010 0 020 0 007 100 A 300k 350 00 k 0 040 0 010 0 040 0 007 5 A 3M 3 500 0 M 0 200 0 010 0 200 0 007 500nA 6 For negative values to 10 f s 7 The maxi...

Страница 12: ...TTACHMENT L2105 2 m 6 56 ft RS 232C CABLE 9637 for PC connection 9pin 9pin cross 1 8 m 5 91 ft RS 232C CABLE 9638 for PC connection 9pin 25pin cross 1 8 m 5 91 ft GP IB CONNECTOR CABLE 9151 02 2 m 6 5...

Отзывы: