9.4 Saving, Display and Deleting Measurement Data
165
8
9
Chap
ter 9
Data Sav
ing a
nd File
Operations
(SYSTEM-MEMOR
Y
screen)
9
Characteristics selected with the
[Recording Items]
setting are all automatically saved to the SD memory
card in the binary format. Up to 100 measurement data files can be created on a single date.
Recording times for (reference value) a Z4001 SD Memory Card 2 GB
(Repeat Record: 1 Week, Repeat Number: 55 times)
• Recording times do not account for event data and screen copy data. Recording times may be short-
ened when event data and screen copy data are stored on the card.
• Recording times are not dependent on connections.
• When repeated recording is set to
[OFF]
, the maximum recording time is 35 days.
• When repeated recording is set to
[1 Day]
, the maximum recording time is 366 days.
• When repeated recording is set to
[1 Week]
, the maximum recording time is 55 weeks.
• Harmonics order data is not saved for
[Power]
, but it is saved in THD.
9.4 Saving, Display and Deleting Measurement
Data
Saving data
If an SD memory card is not inserted into the instrument, measurement data will not be
saved.
Save
procedure
1.
Set the recorded items and TIME PLOT interval.
(See "Recording Items" (p.78), "TIME PLOT Interval" (p.79))
2.
Set the recording start time and end time (as necessary).
(See "Time Start" (p.80))
3.
Press the
key to start recording.
(To cancel recording, press the
key again.)
(A folder will be automatically created, and the data will be stored there. See 9.3 (p.163).)
Save
destination:
SD memory card
File names:
Filenames are automatically created based on the start time and date and given an extension of
“ITV” (time series measurement normal binary data) or “FLC” (time series measurement flicker
data). Numbering starts at 0000 and goes to 9999.
Example: TP0000.ITV (the first set of time series measurement normal binary data saved in the folder)
TIME PLOT interval
Recording parameter setting
All data
(Saves all data)
Power and Harmonic (Saves
RMS values and harmonics)
Power (Saves RMS
values only)
1 second
16.6 hours
23.2 hours
11.9 days
3 seconds
2.1days
2.9 days
35.8 days
15 seconds
10.4 days
14.5 days
25.5 weeks
30 seconds
20.7days
29 days
51 weeks
1 minute
41.5 days
8.3 weeks
55 weeks
5 minutes
29.6 weeks
41.5 weeks
55 weeks
10 minutes
55 weeks
55 weeks
55 weeks
15 minutes
55 weeks
55 weeks
55 weeks
30 minutes
55 weeks
55 weeks
55 weeks
1 hour
55 weeks
55 weeks
55 weeks
2 hours
55 weeks
55 weeks
55 weeks
150/180 /1200wave (Approx. 3 sec) 2.1 days
2.9 days
35.8 days
Remaining storage time
The remaining storage time on the SD memory card being used is displayed when setting the recorded items
and TIME PLOT interval. The time is calculated and displayed based on the SD memory card’s storage capac-
ity, the number of items being recorded, and the TIMEPOT interval time. This calculation does not take event
data into account, so the recording time may vary significantly with the number of events.
HIOKI PQ3198A961-03
Содержание PQ3198
Страница 2: ...HIOKI PQ3198A961 03...
Страница 6: ...Contents iv HIOKI PQ3198A961 03...
Страница 20: ...Usage Notes 14 HIOKI PQ3198A961 03...
Страница 44: ...2 3 Display Items and Screen Types 38 HIOKI PQ3198A961 03...
Страница 58: ...3 8 Turning the Power On and Off Setting the Default Language 52 HIOKI PQ3198A961 03...
Страница 102: ...5 8 Factory Settings 96 HIOKI PQ3198A961 03...
Страница 116: ...6 4 Displaying Harmonics 110 Holding the display Hold Measured values and waveforms will be held HIOKI PQ3198A961 03...
Страница 198: ...12 4 Downloading Recorded Data to Computer 192 HIOKI PQ3198A961 03...
Страница 264: ...14 4 Disposing of the Instrument 258 HIOKI PQ3198A961 03...
Страница 296: ...A32 HIOKI PQ3198A961 03...
Страница 299: ...Index Index 3 Index Wiring 73 Z Zero adjustment 53 Zero phase A28 HIOKI PQ3198A961 03...
Страница 300: ...Index Index 4 HIOKI PQ3198A961 03...
Страница 301: ...HIOKI PQ3198A961 03...
Страница 302: ...HIOKI PQ3198A961 03...
Страница 303: ...HIOKI PQ3198A961 03...
Страница 304: ...www hioki com HIOKI PQ3198A961 03...