5.2 Changing the Recording Settings
78
Sets the type of measurement data.
"Key operation during configuration" (p.77)
Note: If 400 Hz is selected,
[All data]
∗
can not be selected.
Recording Items
Setting Contents:(
∗
: Default setting)
All data
∗
Records all the calculation values.
Power and Harmonic
Records all calculation values except inter-harmonics.
Power
Records all calculation values except harmonics and inter-harmonics.
Recording items
Power
Power and
Harmonic
All data
Recording items
Power
Power and
Harmonic
All data
RMS voltage
refreshed each half-cycle
Instantaneous flicker
value
RMS current
refreshed each half-cycle
Integral power
Frequency
200 ms
Harmonic voltage
—
Frequency wave
Harmonic current
—
10-sec
frequency
Harmonic power
—
Voltage RMS
Phase difference of
harmonic voltage and
harmonic current
—
Current RMS
High-order harmonic
voltage phase angle
—
Voltage
waveform peak
High-order harmonic
current phase angle
—
Current
waveform peak
Inter-harmonic voltage
—
—
Active power
Inter-harmonic current
—
—
Apparent Power
THD Voltage Percentage
Reactive Power
THD current percentage
Power factor/displace-
ment power factor
High-order harmonic
voltage component
Efficiency
Mains signaling voltage
Voltage
unbalance factor
High-order harmonic
current component
Current
unbalance factor
K factor
Flicker
(
Δ
V10/ Pst, Plt)
Detailed trend graphs are always displayed with maximum and minimum values.
HIOKI PQ3198A961-03
Содержание PQ3198
Страница 2: ...HIOKI PQ3198A961 03...
Страница 6: ...Contents iv HIOKI PQ3198A961 03...
Страница 20: ...Usage Notes 14 HIOKI PQ3198A961 03...
Страница 44: ...2 3 Display Items and Screen Types 38 HIOKI PQ3198A961 03...
Страница 58: ...3 8 Turning the Power On and Off Setting the Default Language 52 HIOKI PQ3198A961 03...
Страница 102: ...5 8 Factory Settings 96 HIOKI PQ3198A961 03...
Страница 116: ...6 4 Displaying Harmonics 110 Holding the display Hold Measured values and waveforms will be held HIOKI PQ3198A961 03...
Страница 198: ...12 4 Downloading Recorded Data to Computer 192 HIOKI PQ3198A961 03...
Страница 264: ...14 4 Disposing of the Instrument 258 HIOKI PQ3198A961 03...
Страница 296: ...A32 HIOKI PQ3198A961 03...
Страница 299: ...Index Index 3 Index Wiring 73 Z Zero adjustment 53 Zero phase A28 HIOKI PQ3198A961 03...
Страница 300: ...Index Index 4 HIOKI PQ3198A961 03...
Страница 301: ...HIOKI PQ3198A961 03...
Страница 302: ...HIOKI PQ3198A961 03...
Страница 303: ...HIOKI PQ3198A961 03...
Страница 304: ...www hioki com HIOKI PQ3198A961 03...