background image

9651

CLAMP ON SENSOR

Instruction Manual

Oct.2015 Revised edition8 Printed in Japan

9651A980-08 15-10H

Introduction

Overview

Inspection

Preliminary Checks

Safety

DANGER

This product is designed to conform to IEC 61010 Safety

Standards, and has been thoroughly tested for safety prior to

shipment. However, mishandling during use could result in injury

or death, as well as damage to the product. Be certain that you

understand the instructions and precautions in the manual before

use. We disclaim any responsibility for accidents or injuries not

resulting directly from product defects.

Indicates cautions and hazards. When the symbol is

printed on the product, refer to a corresponding

topic in the Instruction Manual.

Indicates AC (Alternating Current).
Indicates a double-insulated device.
Indicates that the instrument may be connected to or

disconnected from a live circuit.

DANGER

Indicates that incorrect operation presents an

extreme hazard that could result in serious injury or

death to the user.

WARNING

Indicates that incorrect operation presents a

significant hazard that could result in serious injury

or death to the user.

CAUTION

Indicates that incorrect operation presents a

possibility of injury to the user or damage to the

product.

NOTE

Advisory items related to performance or correct

operation of the product.

Notes on Use

DANGER

To avoid short circuits and potentially life-threatening
hazards, never attach the clamp to a circuit that operates at
more than the 600V rms.
Clamp sensor should only be connected to the secondary side
of a breaker, so the breaker can prevent an accident if a short
circuit occurs. Connections should never be made to the
primary side of a breaker, because unrestricted current flow
could cause a serious accident if a short circuit occurs.

WARNING

To avoid electric shock, do not allow the product to get wet,
and do not use it when your hands are wet.

To avoid electric shock when measuring live lines, wear
appropriate protective gear, such as insulated rubber
gloves, boots and a safety helmet.

Note that the product may be damaged if current exceeding
the selected measurement range is applied for a long time.

CAUTION

Do not store or use the product where it could be exposed to

direct sunlight, high temperature or humidity, or condensation.

Under such conditions, the product may be damaged and

insulation may deteriorate so that it no longer meets

specifications.

To avoid damage to the product, protect it from vibration or

shock during transport and handling, and be especially careful to

avoid dropping.

NOTE

Accurate measurement may be impossible in the presence of strong

magnetic fields, such as near transformers and high-current conductors, or

in the presence of strong electromagnetic fields such as near radio

transmitters.

Part Names

Jaws

Output connector

Cable

Ferrite core

Measurement Procedure

CAUTION

To avoid damaging the output cable, grasp the connector, not

the cable, when unplugging the cable.

To prevent damage to the product and sensor, never connect

or disconnect a sensor while the power is on.

Specifications

Conditions of

guaranteed accuracy

Guaranteed accuracy period :1 year

Guaranteed accuracy period after

adjustment :1year

Opening and closing of the jaws:10000

times or less

Accuracy guarantee for temperature

and humidity:23

±

5

(73

±

9 ), 80% RH or less

Rated primary current

500 A AC (f.s.)

Rated secondary current 500 mA AC
Secondary current

amplitude accuracy

1.5% rdg. 0.03%f.s.

(Regarding the accuracy: refer to the

specification of the each unit that you

use with this clamp on sensor)

(f.s. 500 A, 50 Hz/60 Hz, at the jaws

center)

Amplitude frequency

charactristics

Within 3% at 40 Hz to 1 kHz

(Deviation from accuracy)

Maximum input current

600 A continuous at 45 Hz to 66 Hz

Dielictric strength

7060 V rms AC (Sensitive current 1

mA),50 Hz/60 Hz, 1 minute, between the

jaws and the cable Output connector

Maximum rated voltage

to earth

Max. 600 V rms

Operating temperature

and humidity range

0

to 50

(32 to 122 ), Max. 80

%RH (no condensation)

Storage temperature

and humidity range

-10

to 60

(14

to 140 ), Max. 80

%RH (no condensation)

Location for use

Altitude up to 2000 m (6562 feet), Indoors

Standards applying

Safety EN61010 Measurement

Category III Pollution Degree 2

(anticipated transient overvoltage 6000

V)EMC E N61326

Diameter of measurable conductor

Within

φ

46 mm (1.81")

cable length

Approx. 3 m (118.11")

External dimensions

Approx. 78 W 152 H 42 D mm (2.8"

W 5.94" H 1.65" D) (excluding

protrusions)

Mass

Approx. 340 g (12 oz.)

Accessories

Instruction manual

Ma

ximu

m i

np

ut cu

rre

nt (

Ar

ms)

Frequency (Hz)

Figure 1

Maintenance and Service

Warranty

Warranty malfunctions occurring under conditions of normal use in

conformity with the Instruction Manual and Product Precautionary

Markings will be repaired free of charge. This warranty is valid for a

period of one (1) year from the date of purchase. Please contact

the distributor from which you purchased the product for further

information on warranty provisions.

Thank you for purchasing the HIOKI 9651 CLAMP ON SENSOR.

To obtain maximum performance from the product, please read this

manual first, and keep it handy for future reference.

The 9651 is current output type clamp on sensor, which is applicable

to 500A AC current measurements. The instrument can be used to

measure alternating current on a live power line without the need to

cut the wire. Easy operation and connection make them useful for

measuring alternating current and power in various fields.

When you receive the product, inspect it carefully If damage is

evident, or if it fails to operate according to the specifications,

contact your dealer.

Before using the product the first time, verify that it operates normally

to ensure that the no damage occurred during storage or shipping. If

you find any damage, contact your dealer.

Before using the product, make sure that the insulation on the cable

is undamaged and that no bare conductors are improperly exposed.

Using the product in such conditions could cause an electric shock,

so contact your dealer for repair.

Safety symbols

This manual contains information and warnings essential for safe

operation of the product and for maintaining it in safe operating

condition. Before using the product, be sure to carefully read the

following safety notes.

The following symbols in this manual indicate the relative importance

of cautions and warnings.

Measurement categories

This product complies with CAT III safety requirements.

To ensure safe operation of measurement products, IEC 61010 establishes

safety standards for various electrical environments, categorized as CAT II to

CAT IV, and called measurement categories. These are defined as follows.

CAT II: Pr imary electrical circuits in equipment connected to an AC

electrical outlet by a power cord (portable tools, household

appliances, etc.)

CAT II covers directly measuring electrical outlet receptacles.

CAT III: Pr imary electrical circuits of heavy equipment (fixed installations)

connected directly to the distribution panel, and feeders from the

distribution panel to outlets.

CAT IV: The circuit from the service drop to the service entrance, and to

the power meter and primary overcurrent protection device

(distribution panel).

Using a measurement product in an environment designated with a higher-

numbered category than that for which the product is rated could result in a

severe accident, and must be carefully avoided.

Use of a measurement instrument that is not CAT-rated in CAT II to CAT IV

measurement applications could result in a severe accident, and must be

carefully avoided.

Follow these precautions to ensure safe operation and to obtain the

full benefits of the various functions.

1. Connect the output connector to the clamp terminal of the unit.

2. Open the jaws, then clamp the conductor.

Make sure that only one conductor is in the jaws.

3. Make sure that the tip of jaws are fully closed.

Cleaning the unit

To clean the product, wipe it gently with a soft cloth moistened with

water or mild detergent. .

Service

If the product seems to be malfunctioning, contact your dealer.

Pack the product carefully so that it will not be damaged during

shipment, and include a detailed written description of the

problem. Dealer cannot be responsible for damage that occurs

during shipment.

www.

.com

[email protected]

1.800.561.8187

Отзывы: