background image

SAFETY REGULATIONS  |  

PAG. 6

 

Verify and check that the voltage connections as well as the auxiliary 
services have been made properly.

 

When installing the battery, first connect the positive terminal and 
after the negative one. Negative pole to the engine block.

 

Check the cyclical direction of the phases is according to the mains.

 

lndividualize the position of the emergency stop button pushers, the 
quick fuel interception valves, the switches and any other emergency 
systems present in the installation.

 

lsolate all the connections and disconnected threads. Don’t leave 
open the terminals of power of the generator.

RAMIRENT

Содержание KT12000

Страница 1: ...INSTALLATION USE AND MAINTENANCE MANUAL LIGHTING TOWERS APOLO KIT TOWER KT8000 KT12000 R A M I R E N T...

Страница 2: ...ion 4 2 Safety regulations 7 3 Lighting tower composition and location of its components 9 4 Technical information 10 5 Start up 14 6 Operations to carry out after use 15 7 Maintenance 15 8 Failures 1...

Страница 3: ...ions HIMOINSA advises that the validity of the information in this handbook refers to the date that it was issued as several aspects such as the technological developments new regulations or updates a...

Страница 4: ...er wearing loose clothes or objects that may be attracted by the airflow or by the mobile parts of the engine lt is forbidden to dismount or disable any safety device lt is forbidden to lean on the Li...

Страница 5: ...ssible in order to avoid flare risks check that there is a grounds installation and that has been made according to Regulations Place a sign NO MANOEUVRING in all the sectioning organs that insulate t...

Страница 6: ...ative one Negative pole to the engine block Check the cyclical direction of the phases is according to the mains lndividualize the position of the emergency stop button pushers the quick fuel intercep...

Страница 7: ...d anodized with a 15 microns layer 3 2 2 SUPPORT FOR SIX PROJECTORS KT8000 Made of quartz iodine with 1 500W power and a flow of 33 100 lumens each The tower has a lighting capacity of 198 000 lumens...

Страница 8: ...rigid shaft articulated nozzle optional 1 hooking on eye 2 hiding jockey wheel 3 4 extensible legs protected with nylon in all their surface 4 on the chassis it has 4 lifting eyes clearly indicated 5...

Страница 9: ...Standard Standard Lamps n 6 x 1500 W 6 x 2000 W Lamps type Quartz Iodine Metal Halide Total lumnes 6 x 33 000W 198 000 6 x 220 000W 1 320 000 Illuminated surface 16 500 m2 110 000 m2 Waterproof contro...

Страница 10: ...ature meter in the center thereof so that the customer can respect working properties of the oil Some oils can lose properties above or below certain temperatures For water oil and diesel levels of th...

Страница 11: ...G SET As shown in the start up procedure described in the instructions of the generating set See Genset manual Extract the legs Fig 3 Put the safety brackets back in again Fig 3 Fig 3 Turn the uppermo...

Страница 12: ...ON Mast start control lt allows the control of the mast through two simple maneuver press buttons located at the waterproof and maneuvering shelter Fig 1 Before moving the mast it is necessary to star...

Страница 13: ...Fig 3 in order to avoid unexpected movements and mast falls because of a loss of load Fig 3 5 9 SWITCHING ON THE SPOTLIGHTS To switch on the spotlights it was enough with connecting the main switch Fi...

Страница 14: ...trol pag 12 6 3 MAIN SWITCH DISCONNECTION Disconnect the main switch in the control and manoeuvring panel 6 4 STOPPING THE GENSET Follow the instructions for the generating set 6 5 DISCONNECTING THE G...

Страница 15: ...draulic bottle has to be carried out every time we start the lighting tower The hoses must be checked every time start up and be replaced when necessary In case of blown bulbs it is advisable to use g...

Страница 16: ...y Himoinsa In the case of Generating sets it is only applicable to those generating sets that operate together with an manual or automated control panel manufactured or and installed by HIMOINSA The G...

Страница 17: ...orage transrportation or installing any kind of use of the equipment over the capacity and limits established by the manufacturer or under conditions different from those recommended failures caused a...

Страница 18: ...ly need of the purchaser The present warranty will not be applicable to the following cases When the documentation warranty purchasing invoice maintenance and use manual may have been altered in any w...

Страница 19: ...nden con la informaci n disponible en el momento de la impresi n HIMOINSA 2015 Todos los derechos reservados HIMOINSA October 2015 FACTORIES SPAIN FRANCE INDIA CHINA USA BRAZIL SUBSIDIARIES PORTUGAL S...