*2268128*
2268128
English
5
3
Description
3.1
Product overview
@
Transport handle (extending)
;
Lashing loop for
Hilti
case
=
Carrying handle
%
Power outlet on the appliance (only
XE
)
&
Display and control panel
(
Blanking cover for wireless module (optional)
)
Control switch
+
Connection for suction hose
§
Container latch (2 of)
/
Supply cord
:
Securing hook (2 of) with rubber strap
∙
Suction head
$
Waste material container
£
Filter cassette with retainer
3.2
Intended use
The products described here are industrial vacuum cleaners designed for universal, commercial use. They
may be used for wet or dry applications.
Use of the product to clean down persons or animals is not permissible. Underwater use is not permissible.
▶
Before beginning work with the product, find out how to operate it correctly and about any hazards
associated with the materials you will be working with and how these materials can be disposed of safely.
▶
Do not use the product for continuous, stationary operation in automatic or semi-automatic systems.
▶
To reduce the risk of injury, use only genuine
Hilti
accessories and accessory tools.
▶
Use an anti-static suction hose in order to avoid electrostatic effects.
▶
Do not vacuum up objects or materials that could cause injury by piercing through the dust bag (e.g.
pointed or sharp objects).
▶
Do not stand on the product (do not use it as a substitute for a ladder).
▶
Comply with the accident prevention regulations applicable in your country.
Permissible applications:
With vacuum cleaners it is necessary to ensure an adequate rate of air exchange (L) in the room in
situations where the expelled air is returned to the room.
Comply with national regulations!
▶
Vacuuming up large quantities of dust from work with
Hilti
diamond grinders, cut-off saws, rotary
hammers and core drilling machines using dry-cutting core bits.
▶
Vacuuming up mineral drilling slurry from working with
Hilti
diamond core bits or
Hilti
diamond saws,
and liquids up to a temperature of max. 60 °C (140 °F).
▶
Vacuuming up oil and liquid media up to a temperature of max. 60 °C (140 °F).
▶
Wet and dry cleaning of wall and floor surfaces.
The products described here meet the requirements of the OSHA 1926.1153 Regulation, Table 1.
3.3
Possible misuse
▶
Do not use the vacuum cleaner to vacuum up asbestos.
▶
Do not operate the vacuum cleaner when it is laid flat.