background image

17

en

Hilti power tools have been designed to work opti-
mally as a system together with Hilti insert tools.
Accordingly, highest performance and longest life
expectancy can be achieved when you use this pow-
er tool with Hilti insert tools.

A comprehensive pro-

gramme of insert tools and accessories is available for
the TE-C system 

. Details of the entire programme

can be found in the current Hilti product catalogue.
Should you require insert tools not included in the stan-
dard programme, please contact the Hilti customer ser-
vice department or your Hilti sales representative. Hilti
offers a comprehensive range of special insert tools in
professional quality.

Check your insert tools at regular intervals and replace
them in good time. A damaged or badly worn connec-
tion end may result in damage to the power tool. Drill
bits with chipped or broken carbide tips may no longer
drill holes of the specified diameter, thus influencing
their suitability for anchor fastenings. 
Please observe the instructions on care and mainte-
nance of your insert tools given in the following section.

Dust removal (TE DRS-S) 

A DRS extraction head can be attached to the side han-
dle / depth gauge. An industrial vacuum cleaner is used
to remove drilling dust and fragments

.

Care and maintenance

-CAUTION-

Disconnect the supply cord plug from the power out-

let.

Care of insert tools

Clean off dirt and dust deposits adhering to the insert

tools and protect them from corrosion by wiping the

insert tools from time to time with an oil-soaked rag.

Care of the power tool

-CAUTION-

Keep the power tool, especially its grip surfaces, clean

and free from oil and grease. Do not use cleaning

agents which contain silicone.

The outer casing of the power tool is made froM impact-

resistant plastic. Sections of the grip are made from a

synthetic rubber material.

Never operate the power tool when the ventilation slots

are blocked. Clean the ventilation slots carefully using

a dry brush. Do not permit foreign objects to enter the

interior of the power tool. Clean the outside of the pow-

Rotary-only drilling (without hammering action)
(TE 2 / TE 2-E / TE 2-S)

Turn the function selection switch to the drilling posi-
tion ( ) 

. When the switch is in this position, only the

rotary movement is transmitted to the TE-C insert tool
or chuck adaptor for insert tools with cylindrical shanks.

Rotary-only drilling (without hammering action)
(TE 2-M)

Turn the function selection switch to the 1st gear or 2nd
gear drilling position 

. When the switch is in these

positions, only the rotary movement is transmitted to
the TE-C insert tool or quick-release chuck.
Use of a high spindle speed can be advantageous when
drilling in metal or wood. For higher drilling speed, the
function selection switch must be engaged in the 2nd
gear position ( 2) 

Changing the chuck (TE 2-M)

Pull the chuck release ring towards the front and remove
the chuck completely. When fitting the chuck, pull the
release ring towards the front and hold it in this posi-
tion. Push the chuck onto the guide tube as far as it will
go and release the ring. Rotage the chuck until it engages
and the ring snaps back into its original position 

. The

TE-C interchangeable chuck or quick-release inter-
changeable chuck may be fitted to the TE 2-M with chuck
interface 

.

Drilling using the depth gauge

We recommend the use of the depth gauge for drilling
holes accurately to the desired depth. The depth gauge
is integrated in the side handle, which can be pivoted
and locked in position. Release the side handle (turn
counter-clockwise), set the depth gauge to the desired
drilling depth and tighten the side handle (turn clock-
wise) 

.

Forwards / reverse rotation
(TE 2 / TE 2-S / TE 2-M)

For screwdriving, the desired direction of rotation can
be selected simply by moving the switch 

 

.

For  forwards rotation, select position ( ) and for  rever -
se rotation, select position ( ). 
When the tool is operated in reverse rotation, the func-
tion selection switch 

should be engaged in the posi-

tion for drilling without hammering action ( / 1st gear).
For drilling, always ensure that forwards rotation 
( ) is selected.

Insert tools and accessories

Use only insert tools with TE-C connection end or straight
shank bits with quick release chuck or adaptor 

.

7b

7d

7d

7b

02_BA_TE2_S_M_P1_en.qxd:02_BA_TE2_S_M_P1_en.qxd  29.9.2012  9:53 Uhr  Seite 17

Printed: 14.02.2014 | Doc-Nr: PUB / 5170540 / 000 / 00

Содержание TE 2-M

Страница 1: ... de instruções pt Gebruiksaanwijzing nl Οδηγιες χρησεως el Használati utasítás hu Instrukcja obsługi pl Инструкция по зксплуатации ru Návod k obsluze cs Návod na obsluhu sk Upute za uporabu hr Navodila za uporabo sl Kullan m k lavuzu tr IНСТРУКЦIЯ З ЕКСПЛУАТАЦIЇ uk TE 2 TE 2 S TE 2 M Printed 14 02 2014 Doc Nr PUB 5170540 000 00 ...

Страница 2: ...TE2 M TE 2 S 1 4 3 9 8 7 6 5 TE 2 TE 2 E TE 2 S 1 2 1 2 TE2 M 2 1 Printed 14 02 2014 Doc Nr PUB 5170540 000 00 ...

Страница 3: ...TE2 M TE2 M TE2 M 1 2 2 4 3 5b 5a Printed 14 02 2014 Doc Nr PUB 5170540 000 00 ...

Страница 4: ...TE 2 TE 2 S TE 2 M 1 2 6 Printed 14 02 2014 Doc Nr PUB 5170540 000 00 ...

Страница 5: ...TE2 TE2 E TE2 S TE2 M 10 8 7 7 9 TE2 M 1 2 1 2 7 1 2 1 2 1 2 7a 7b 7a 7b 7c 7a 7b 7d Printed 14 02 2014 Doc Nr PUB 5170540 000 00 ...

Страница 6: ... per minute Alternating current Nominal speed under no load Diameter 11 en Safety notices and their meaning It is essential that the operating instructions are read before the tool is operated for the first time Always keep these operating instructions together with the tool Ensure that the operating instructions are with the tool when it is given to other persons Operating controls 햲 Chuck releas...

Страница 7: ...hammer with pneumatic hammering mech anism designed for professional use The following items are supplied power tool quick release chuck TE2 M operating instructions grease except TE 2 E toolbox side handle cleaning cloth Depth gauge The following conditions must always be observed when the tool is in use The tool must be connected to an alternating current electric supply in compliance with the i...

Страница 8: ...ain applications of the tool However if the tool is used for different applications with different accessories or poorly maintained the vibration emission may differ This may significantly increase the exposure level over the total working period An estimation of the level of exposure to vibration should also take into account the times when the tool is switched off or when it is running but not a...

Страница 9: ...re the switch is in the off position before connecting to power source and or battery pack picking up or carrying the tool Carrying power tools with your finger on the switch or energising power tools that have the switch on invites accidents d Remove any adjusting key or wrench before turn ing the power tool on A wrench or a key left attached to a rotating part of the power tool may result in per...

Страница 10: ...lass P2 is recommended Follow national requirements for the materials you want to work with 3 2 Power tool use and care a Secure the workpiece Use clamps or a vice to hold the workpiece in place The workpiece is thus held more securely than by hand and both hands remain free to operate the tool b Ensure that the insert tools used are equipped with the appropriate connection end system and that the...

Страница 11: ...he qual ity of the holes drilled 4 Connect the supply cord to the power supply 5 Pivot the side handle with or without the depth gauge to the desired angle and tighten the handle to lock it in this position Check that the side handle is seated and attached securely 6 Bring the tip of the drill bit into contact with the work surface at the position where the hole is to be drilled and press the cont...

Страница 12: ...ior of the power tool Clean the outside of the pow Rotary only drilling without hammering action TE2 TE2 E TE2 S Turn the function selection switch to the drilling posi tion When the switch is in this position only the rotary movement is transmitted to the TE C insert tool or chuck adaptor for insert tools with cylindrical shanks Rotary only drilling without hammering action TE2 M Turn the functio...

Страница 13: ...Check all external parts of the power tool for damage at regular intervals and check that all controls operate fault lessly Do not operate the power tool if parts are dam aged or when the controls do not function faultlessly If necessary the power tool should be repaired by Hilti Service Checking the power tool after care and maintenance After carrying out care and maintenance work on the power to...

Страница 14: ...go Function selection switch set Set function selection switch to precision hammering action to hammer drilling Forwards reverse switch set Set forwards reverse switch to reserve when drilling to forwards Drill bit cannot be released Chuck not opened fully Pull the chuck locking sleeve back as far as it will go and remove the insert tool EC declaration of conformity original Description Rotary Ham...

Страница 15: ...20 ...

Страница 16: ... Tel 423 2342111 Fax 423 2342965 www hilti com Hilti registered trademark of Hilti Corp Schaan W 2740 0912 10 Pos 1 1 Printed in China 2012 Right of technical and programme changes reserved S E O 2059547 A2 Printed 14 02 2014 Doc Nr PUB 5170540 000 00 ...

Отзывы: