6.3 Fitting the battery
CAUTION
Before fitting the battery, check that the power tool is switched off and
that the safety lock is engaged (forward/reverse switch in the middle
position). Use only the Hilti batteries approved for use with this power
tool.
CAUTION
Check that the terminals on the battery and in the power tool are free
from foreign objects before inserting the battery in the power tool.
1. Push the battery into the power tool from the rear as far as it will go and
until it is heard to engage with a double click.
2.
CAUTION A falling battery may present a risk of injury to yourself or
others.
Check that the battery is seated securely in the power tool.
6.4 Removing the battery
2
1. Press the release button.
2. Pull the battery out of the power tool toward the rear.
6.5 Transport and storage of battery packs
Pull the battery pack out of the locked position (working position) and move
it into the first click-stop position (transport position).
If you disconnect a battery pack from the power tool for transport or storage,
make sure that the contacts of the battery pack are not short-circuited.
Remove loose metal parts such as screws, nails, clamps, loose screw bits,
wires or metal swarf from the case, toolbox or transport container, or prevent
these parts from coming into contact with the battery packs.
Observe national and international transport regulations when shipping
battery packs (transportation by road, rail, sea or air).
6.6 Fitting the side handle
3
1. Set the forward / reverse switch to the middle position (transport lock)
or remove the battery from the power tool.
2. Release the side handle clamping band by turning the handle counter-
clockwise.
3. Slide the side handle clamping band over the chuck and onto the
clamping section at the front end of the power tool.
4. Pivot the side handle into the desired position.
5. Secure the side handle by turning the handle clockwise.
6. Check that the side handle holds securely.
Printed: 30.09.2013 | Doc-Nr: PUB / 5071630 / 000 / 02