![Hilti PMP 34-F Скачать руководство пользователя страница 9](http://html.mh-extra.com/html/hilti/pmp-34-f/pmp-34-f_operating-instructions-manual_2135748009.webp)
4. Technical data
Range
30 m
Range depends on the brightness of ambient light.
Right of technical changes reserved.
Accuracy of the front beam (horizontal)
Temperature 25°C: ±3 mm at 10 m (
{
/
೩
" at 30 ft)
Accuracy of the perpendicular (horizontal) beam
Temperature 25°C: ±3 mm at 10 m (
{
/
೩
" at 30 ft)
Angle accuracy (horizontal)
Temperature 25°C: 90° ±60"
Accuracy of the plumb beam
Temperature 25°C: ±3 mm at 10 m (
{
/
೩
" at 30 ft)
Self-levelling time (approx.)
3 s
Laser class: Class 2
Temperature 25°C, Visible: 635 Nm
IEC 825
ತ
1:2003, EN 60825
ತ
01:2003,
CFR 21 § 1040 (FDA)
Beam diameter
Temperature 25°C, Distance 5 m:
ู
3 mm
Temperature 25°C, Distance 20 m:
ู
12 mm
Self-leveling range
±5°
Automatic cut-out
Activated after: 15 min
Operating status indicator
LED and laser beams
Power supply
AA
ತ
size batteries, Alkaline batteries: 4
Battery life
Alkaline battery, Temperature 25°C
(+77°F): Min. 20 h
Operating temperature range
ತ
10 - 40°C (+14 °F to 104 °F)
Storage temperature
ತ
20 - 63°C (-4 °F to 145 °F)
Dust and water spray protection (except battery
compartment)
IP 54
IEC 529
Weight
Without batteries: 660 g
Dimensions
138 mm X 51 mm X 126 mm
5. Safety rules
5.1 Basic information concerning safety
In addition to the information relevant to safety
given in each of the sections of these operating
instructions, the following points must be strictly
observed at all times.
5.2 General safety rules
a)
Do not render safety devices ineffective and do
not remove information and warning notices.
b)
The laser visibility glasses have no protective
function and do not protect your eyes from laser
light. As the laser visibility glasses restrict color
vision, they should be worn only when working
with this tool and must not be worn while driving
a vehicle on a public road.
c)
Keep laser tools out of reach of children.
d) Failure to follow the correct procedures when
opening the tool may cause emission of laser
radiation in excess of class 2.
Have the tool
repaired only at a Hilti service center.
e)
Do not open the casing of the tool.
f)
Check the condition of the tool before use. If the
tool is found to be damaged, have it repaired at
a Hilti service center.
g)
Check the accuracy of the tool before using it to
take measurements.
h)
The tool must be checked at a Hilti service
center after it has been dropped or subjected to
other mechanical stresses.
i)
When the tool is brought into a warm environ-
ment from very cold conditions, or vice-versa,
allow it to become acclimatized before use.
e
n
4
Printed: 07.07.2013 | Doc-Nr: PUB / 5071666 / 000 / 00
Содержание PMP 34-F
Страница 2: ...1 2 3 5 4 1 Printed 07 07 2013 Doc Nr PUB 5071666 000 00...
Страница 3: ...1 2 3 4 2 1 2 3 3 4 90 90 5 6 Printed 07 07 2013 Doc Nr PUB 5071666 000 00...
Страница 4: ...7 8 Printed 07 07 2013 Doc Nr PUB 5071666 000 00...
Страница 5: ...9 10 11 12 13 Printed 07 07 2013 Doc Nr PUB 5071666 000 00...
Страница 25: ...da 20 Printed 07 07 2013 Doc Nr PUB 5071666 000 00...
Страница 35: ...no 30 Printed 07 07 2013 Doc Nr PUB 5071666 000 00...
Страница 45: ...sv 40 Printed 07 07 2013 Doc Nr PUB 5071666 000 00...
Страница 64: ...9 7 A B B Hilti Hilti A Hilti A B Hilti 10 Hilti Hilti Hilti ru 59 Printed 07 07 2013 Doc Nr PUB 5071666 000 00...