English
23
10.2 Cleaning the fastening tool
Note
The fastening tool must be cleaned and serviced regularly. We recommend that a cleaning service is
carried out, at the latest, after driving 25,000 fasteners.
▶
Clean the fastening tool, or have it cleaned, if malfunctions such as misfiring occur increasingly.
▶
For cleaning, use the cleaning set (available as an accessory) and observe the illustrated cleaning
instructions enclosed with it.
10.3 Maintenance
▶
To help ensure safe and reliable operation, use only genuine Hilti spare parts and consumables. Spare
parts, consumables and accessories approved by Hilti for use with the product can be found at your
local
Hilti
Center or online at:
www.hilti.group
.
▶
Check all external parts of the fastening tool for signs of damage at regular intervals and make sure that
all the controls function correctly.
▶
Do not use the fastening tool if parts are damaged or if the controls do not function correctly.
▶
Have a defective fastening tool repaired by
Hilti
Service.
10.4 Checks after care and maintenance work
▶
After maintenance, check that the fastener guide is fitted → page 22.
11 Troubleshooting
If the trouble you are experiencing is not listed in this table or you are unable to remedy the problem by
yourself, please contact
Hilti Service
.
Malfunction
Possible cause
Action to be taken
Fasteners are frequently
driven to inadequate depth.
Driving power is too low.
▶
Move the fastener driving depth
adjustment slider to the
+
position.
The fasteners are too long.
▶
Use shorter fasteners.
The supporting material is too
hard.
▶
Consider using a DX fastening
tool.
Fasteners are frequently
driven too deeply.
Driving power is too high.
▶
Move the fastener driving depth
adjustment slider to the
‒
position.
The fasteners are too short.
▶
Use longer fasteners.
Fasteners break.
Driving power is too low.
▶
Move the fastener driving depth
adjustment slider to the
+
position.
The fasteners are too long.
▶
Use shorter fasteners.
The supporting material is too
hard.
▶
Consider using a DX fastening
tool.
The fastener guide is not held per-
pendicular to the working surface.
▶
On an even surface use the
support leg and ensure correct
contact with the surface (see
"Support leg" → page 18).