Hilti DX 462 Скачать руководство пользователя страница 5

19

en

4. Check the buffer, piston and fastener guide for wear

and replace the parts if necessary (See 6.3 and 8.4).

5. Clean the tool.
6. Do not continue to use the tool if the problem per-

sists after carrying out the steps described above.
Have the tool checked and repaired if necessary at a
Hilti repair center.

Never attempt to pry a cartridge from the magazine

strip or the tool.

Keep the arms flexed when the tool is fired (do not

straighten the arms).

Never leave the loaded tool unattended.

Always unload the tool before beginning cleaning,

servicing or changing parts and before storage.

Store cartridges and unused tools unloaded, in a dry,

high or locked place out of the reach of children.

5.7 Temperature

Do not disassemble the tool while it is hot.

Never exceed the recommended maximum fastener

driving rate (number of fastenings per hour). The tool
may otherwise overheat.

Should the plastic cartridge strip begin to melt, stop

using the tool immediately and allow it to cool down.

5.8 Requirements to be met by users

The tool is intended for professional use.

The tool may be operated, serviced and repaired only

by authorised, trained personnel. This personnel must
be informed of any special hazards that may be encoun-
tered.

Proceed carefully and do not use the tool if your full

attention is not on the job.

Stop working with the tool if you feel unwell.

5.9 Personal protective equipment

The operator and other persons in the immediate vicin-

ity must always wear eye protection, a hard hat and ear
protection.

6. Before use

쎱쎱

6.1

Tool inspection

Ensure that there is no cartridge strip in the tool. If

there is a cartridge strip in the tool, remove it by hand
from the tool.

Check all external parts of the tool for damage at reg-

ular intervals and check that all controls operate prop-
erly. Do not operate the tool when parts are damaged or
when the controls do not operate properly. If necessary,
have the tool repaired at a Hilti service centre.

Check the buffer and piston for wear (see “8. Care

and maintenance”).

6.2 Choosing the right fastener guide / piston / fas-
tener combination

Use of the wrong combination may result in damage to
the tool and / or affect fastening quality (see table on last
page of these instructions).

쎱쎱

6.3

Changing the fastener guide

1. Ensure that no cartridge strip or fastener is loaded in

the tool. Remove the cartridge strip by pulling it
upwards out of the tool and remove the fastener from
the fastener guide.

2. Press the release button on the side of the fastener

guide.

3. Unscrew the fastener guide.
4. Check the buffer and piston for wear (see "Care and

maintenance").

5. Push the piston into the tool as far as it will go.
6. Press the buffer onto the fastener guide until it snaps

into place.

7. Push the fastener guide firmly onto the piston return

unit.

8. Screw the fastener guide onto the tool until it engages.

Содержание DX 462

Страница 1: ...ty rules 18 6 Before use 19 7 Operation 20 8 Care and maintenance 21 9 Troubleshooting 23 10 Disposal 27 11 Manufacturer s warranty DX tools 27 1 General information 1 1 Signal words and their meaning...

Страница 2: ...he propellant charge is transferred to a piston the accelerated mass of which drives the fas tener into the base material As approximately 95 of the kinetic energy is absorbed by the piston the fasten...

Страница 3: ...andard nail for efficient fastenings on steel With 12 mm washer for higher pull over loads X DAK Nail with stepped shank For fastening on high strength concrete or steel X CR Stainless steel nail for...

Страница 4: ...This tool is designed with the latest available tech nology The tool and its ancillary equipment may present haz ards when used incorrectly by untrained personnel or not as directed 5 5 Make the workp...

Страница 5: ...working with the tool if you feel unwell 5 9 Personal protective equipment The operator and other persons in the immediate vicin ity must always wear eye protection a hard hat and ear protection 6 Bef...

Страница 6: ...the eyes Wear safety goggles and a hard hat users and bystanders X DNI nail concrete steel MD ET SL SD Length of nails for steel Penetration depth ET 22 5 mm nail point must protrude material thickne...

Страница 7: ...section The ventilation slots must be unobstructed and kept clean at all times Do not permit foreign objects to enter the interior of the tool Use a slightly damp cloth to clean the outside of the too...

Страница 8: ...he piston return unit lightly with Hilti spray 8 9 Clean inside the housing 1 Use the large round brush to clean inside the hous ing 2 Spray the inside of the housing lightly with Hilti spray 8 10 Cle...

Страница 9: ...fully back See 9 1 Use longer fastener Use fastener with washer for wood applications Reduce power setting Power regulation Lower cartridge power level Change cartridge strip Clean the cartridge stri...

Страница 10: ...r debris inside the piston return unit Damaged buffer Carbon build up Remove cartridge strip Unscrew piston return unit and push out the piston through the cartridge chamber using the pushrod provided...

Страница 11: ...ridge Base material is spalling Nail bends Hard and or large aggregate in concrete Rebar close to surface of concrete Hard surface steel High strength concrete Hard and or large aggregate in concrete...

Страница 12: ...Use co acting principle fastener guide Switch to more powerful system like DX 750 DX 600 N Try different power setting or different cartridge Try EDNK 20P8H or ENKK 20 S12 for fastening sheet metal Tr...

Страница 13: ...onents and spare parts or other products of equiv alent quality may be used in the tool This warranty provides the free of charge repair or replacement of defective parts only over the entire lifes pa...

Страница 14: ...circumstances of use most powerful cartridge power load in accordance with instructions for use with suitable nail or stud fired vertically downwards into a steel plate and in accordance with the mean...