Cartridge not transported
Cartridge strip cannot be
removed
10
en
Troubleshooting
Fault
Cause
■
Damaged cartridge strip
■
Carbon build up
■
Tool damaged
■
Tool overheated because of high
setting rate
■
Tool damaged
WARNING
Make sure not to crush or pry
on an unfired booster.
■
Bad cartridge
■
Carbon built up
WARNING
Never attempt to pry a cartridge
from the magazine strip of the tool.
Possible remedial measure
■
Change cartridge strip
■
Clean the cartridge strip guide-
way (see 8.4, point 5)
If the problem persists:
■
Contact Hilti Center.
■
Let the tool cool down
■
Then carefully try to remove the
cartridge strip
If not possible:
■
Contact Hilti Center.
■
Manually advance the cartridge
strip one cartridge
If the problem occurs more
often: Clean the tool
If the problem persists:
■
Contact Hilti Center.
■
Tool is compressed too long
while fastening.
■
Fastening frequency is too high
■
Compress the tool a shorter time
while fastening.
■
Remove the cartridge strip
■
Disassemble the gas return unit
(see 8.4) for fast cooling and to
avoid possible damage
If the tool cannot be disassembled:
■
Contact Hilti Center.
Cartridge strip melts
Cartridge cannot be fired
Cartridge falls out of the
cartridge strip
■
Fastening frequency is too high
WARNING
Make sure not to crush or pry
on an unfired booster
■
Immediately discontinue using
the tool and let it cool down
■
Remove cartridge strip
■
Let the tool cool down.
■
Clean the tool and remove loose
cartridge.
If it is impossible to disassemble
the tool:
■
Contact Hilti Center.