Before work starts, remove the air inlet cover.
1. Make sure that the product is steady and cannot topple.
2. To switch on, turn the control switch to the stage 2 position (full power).
3. To switch off, turn the control switch to the
OFF
position.
6.1
Integration into dust-stop partition wall
You can operate the product with an extraction hose or integrate it directly into a dust-stop partition wall with
the dust-stop partition wall adapter and vacuum dust out of the inside of the dust-stop partition wall without
the product being directly in the room. To operate the product with an intake hose connected or integrate
the product directly into a dust-stop partition wall, the shutters on both sides of the product must be closed.
1. Pull the dust-stop partition wall adapter off air inlet cover
(1)
.
2. Position the product at the dust-stop partition wall.
3. Use the dust-stop partition wall adapter to secure the dust-stop partition wall to the air inlet.
Turn the dust-stop partition wall adapter through 180° so that the inner ring fits into the air inlet.
4. If necessary, cut an opening into the dust-stop partition wall secured to the air inlet.
5. Shut off the side filters by pulling the shutter up.
6. Switch the tool on.
6.2
Replacing pre-filters
1. Switch the air cleaner off and wait until the turbine runs down to a complete stop.
2. Open the pre-filter cover
(1)
.
3. Remove the pre-filter and insert a new pre-filter
(2)
.
4. Remove dust residues.
5. Close the pre-filter cover
(3)
.
6.3
Replacing main filters
1. Switch the air cleaner off and wait until the turbine runs down to a complete stop.
2. Open both toggle catches and remove the housing cover by lifting it up
(1)
.
3. Remove heavy accretions of dust inside the housing with a vacuum cleaner.
Ascertain the dust class of the dust and use a vacuum cleaner approved for the dust class.
4. Remove the pre-filters
(2)
.
5. Remove dust residues.
6. Open the rotary catches (3) and replace the main filter
(4)
.
7. Replace the pre-filters
(5)
.
8. Lower the housing cover into position
(6)
and seal the filter cover by closing the toggle catches
(7)
.
7
Care and maintenance
WARNING
Electric shock hazard!
Attempting care and maintenance with the supply cord connected to a power outlet
can lead to severe injury and burns.
▶
Always unplug the supply cord before carrying out care and maintenance tasks.
Care
• Carefully remove stubborn dirt from the tool.
• Clean the air vents carefully with a dry brush.
• Use only a slightly damp cloth to clean the casing. Do not use cleaning agents containing silicone as
they can attack the plastic parts.