Hilmerson Safety Safety Rail System Скачать руководство пользователя страница 6

*Approved fall protection must be utilized while installing bases and guardrails where fall hazards exist. 

Choosing Baseplate Type & Designing a Layout  

   

 

 

 

 

 

 
 

 
 

 
 

 
 

 

 

 

1.

 

Install only on clean, dry, level 
surfaces and determine if you will 

be utilizing penetrating anchored 
bases or non-penetrating weighted 

bases.  
 
 
 

2.

 

Determine the desired protection 

layout before beginning the 
installation process. 
 
 
 

3.

 

All guardrail layouts must be 

designed or approved by a 
competent person. 

 
 
 

4.

 

When using penetrating anchored 

base plates, anchor bolt holes must 
be no less than 6 inches from the 

nearest edge.

 

 
 

5.

 

When using non-penetrating 

weighted base plates, outrigger 
returns are required at the end of 

each protection run installed 
perpendicular to the leading edge 

hazard.

 

 
 
 

 

 

 

 

 

   

 

 

 

   Note:  All guardrail layouts must be designed or approved by a competent person. 
   

 

 

 

 

Содержание Safety Rail System

Страница 1: ...merson Safety Rail System poses a threat to safety and health and may result in death or serious injury to installers users and or third parties Hilmerson Safety and our manufacturer expressly disclai...

Страница 2: ...deck that changes location as additional floor roof or deck or formwork sections are placed or constructed A leading edge is considered an unprotected side and edge OUTRIGGER RETURN A 5 ft or 10 ft gu...

Страница 3: ...nstalled on is capable of supporting the product and personnel installing it A complete assessment of the entire surrounding areas should be made to determine if the walking and working surfaces have...

Страница 4: ...nel 5 5 ft 9ft Adjustable 1 O D x Galvanized 13 gage tube Warning It is recommended that a competent person approve and oversee the installation of this system The Hilmerson Safety Rail System is an e...

Страница 5: ...ade 50 Steel Galvanized E HLM GRBPG Penetrating Anchored Base Plate ASTM A572 Grade 50 Steel Galvanized F HLM GRBPDL Weighted Base Dolly 1 O D x Galvanized 13 gage tube Powder Coated G HLM RS3G 22 34...

Страница 6: ...he desired protection layout before beginning the installation process 3 All guardrail layouts must be designed or approved by a competent person 4 When using penetrating anchored base plates anchor b...

Страница 7: ...gth of f c 3 000 psi normal weight cracked concrete Non penetrating weighted bases are recommended for use on post tension decks or other surfaces where you can t penetrate 2 Pre drill a diameter hole...

Страница 8: ...n 418072 through the top of the base plate and into the pre drilled hole according to Hilti p n 418072 x 3 KWIK HUS EZ KH EZ installation requirements 2 Tighten the anchor bolt until it is seated on...

Страница 9: ...to set up guardrail protection on a wide variety of surfaces but shall be no closer than 18 inches from the leading edge requiring protection unless there is an elevated parapet wall 2 Install only o...

Страница 10: ...hazards exist Installing Guardrail Panels 1 To install guardrail panels on either type of baseplate simply remove a guardrail panel from the mobile cart and seat on the base plate post 2 When seating...

Страница 11: ...stalling Guardrail Panels 3 Install a gravity locking pin through the base plate post and guardrail panel making sure that the loop on the pin falls into the locked position 4 When installing guardrai...

Страница 12: ...return guardrail panels and weighted bases are required to be installed perpendicular to the leading edge at the end of each protection run to provide required counterweight 2 Upon completion of insta...

Страница 13: ...re accurate to a degree consistent with current practice s Hilmerson Safety Services Inc and its affiliates do not assume responsibility for errors or oversights that may result from the use of the in...